D-Dimer Detection Kit (Quantum Dot Fluorescence Immunoassay)
The kit includes a detection card, pipette (optional), ID card (optional), and instruction manual. The detection card consists of a test strip, desiccant, and aluminum foil bag. The ID card is used for calibration by reading the calibration curve specific to the batch. The test strip is composed of absorbent paper, nitrocellulose membrane, sample pad, quantum dot-labeled pad, PVC backing, and plastic casing. The nitrocellulose membrane has a T-line coated with approximately 1.0 mg/mL of mouse anti-human D-dimer monoclonal antibody 2 and a C-line coated with approximately 1.0 mg/mL of goat anti-mouse IgG antibody. The quantum dot-labeled pad contains 0.02-0.2 mg/mL of mouse anti-human D-dimer monoclonal antibody 1 quantum dot conjugate.
Product English Name:
D-Dimer Detection Kit (Quantum Dot Fluorescence Immunoassay)
Alias:
D-Dimer Test Kit,Quantum Dot D-Dimer Assay
Intended Use:
The kit is designed for the clinical quantitative detection of D-dimer levels in human plasma and whole blood. It is used to assess conditions related to blood clotting disorders, such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer Detection Kit (Quantum Dot Fluorescence Immunoassay) is a cutting-edge diagnostic tool designed for the precise measurement of D-dimer levels in human blood. Utilizing advanced quantum dot technology, this kit offers high sensitivity and specificity, making it an essential tool in the diagnosis and management of thrombotic disorders. The kit is user-friendly, with a straightforward procedure that ensures accurate and reliable results.

1. The kit features a highly sensitive quantum dot fluorescence immunoassay, which provides superior detection capabilities compared to traditional methods. This technology enhances the accuracy of D-dimer measurements, even at low concentrations.
2. The test strip is composed of multiple layers, including a nitrocellulose membrane that is specifically coated with antibodies to capture D-dimer molecules. The quantum dot-labeled pad ensures a strong fluorescent signal, which is crucial for precise quantification.
3. The kit is primarily used in clinical settings to diagnose and monitor conditions associated with abnormal blood clotting. It is particularly valuable in emergency situations where rapid and accurate diagnosis is critical.

The D-Dimer Detection Kit (Quantum Dot Fluorescence Immunoassay) is a sophisticated diagnostic tool that combines advanced quantum dot technology with a well-designed test strip. Its high sensitivity and specificity make it an indispensable resource for clinicians dealing with thrombotic disorders. The kit's ease of use and reliability ensure that it is a trusted choice in both routine and emergency medical settings.

Main Features

The D-Dimer Detection Kit offers high sensitivity and specificity, rapid results, and ease of use. It is designed for both routine and emergency clinical settings.

1. High Sensitivity: The quantum dot fluorescence immunoassay provides exceptional sensitivity, allowing for the detection of low D-dimer concentrations with high accuracy.
2. Rapid Results: The kit delivers results quickly, which is crucial in emergency situations where timely diagnosis can significantly impact patient outcomes.
3. User-Friendly Design: The kit is designed for ease of use, with clear instructions and a straightforward procedure that minimizes the risk of user error.
4. Reliable Performance: The kit's components, including the test strip and ID card, are engineered to ensure consistent and reliable performance across different batches.
5. Versatility: The kit can be used with both plasma and whole blood samples, making it adaptable to various clinical settings and patient needs.

The D-Dimer Detection Kit stands out for its high sensitivity, rapid results, and user-friendly design. These features make it an invaluable tool for clinicians, particularly in emergency settings where quick and accurate diagnosis is essential. The kit's reliability and versatility further enhance its utility in a wide range of clinical scenarios.

Clinical Applications

The kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders, including deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.

1. Diagnosis of Deep Vein Thrombosis (DVT): The kit is used to detect elevated D-dimer levels, which are indicative of DVT. This helps in the early diagnosis and management of the condition.
2. Pulmonary Embolism (PE) Detection: Elevated D-dimer levels are also associated with PE. The kit aids in the rapid diagnosis of this life-threatening condition.
3. Monitoring Disseminated Intravascular Coagulation (DIC): The kit is used to monitor D-dimer levels in patients with DIC, helping clinicians assess the severity of the condition and guide treatment.
4. Post-Surgical Monitoring: The kit is used to monitor D-dimer levels in patients post-surgery to detect any signs of abnormal blood clotting.
5. Research Applications: The kit is also used in research settings to study the role of D-dimer in various thrombotic and inflammatory conditions.

The D-Dimer Detection Kit is a versatile tool in clinical practice, used for the diagnosis and monitoring of various thrombotic disorders. Its ability to provide rapid and accurate results makes it particularly valuable in emergency settings. Additionally, its use in research highlights its importance in advancing our understanding of thrombotic and inflammatory diseases.

Purchasing Guide

When purchasing the D-Dimer Detection Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical needs.

1. Product Specifications: Evaluate the kit's sensitivity, specificity, and detection range to ensure it aligns with your diagnostic requirements.
2. Product Types: Choose between different kit formats, such as those designed for plasma or whole blood samples, based on your laboratory's capabilities and patient population.
3. Budget Considerations: Assess the cost-effectiveness of the kit, taking into account the number of tests per kit and the overall value it provides.
4. Usage Scenarios: Consider the clinical settings in which the kit will be used, such as emergency rooms, outpatient clinics, or research laboratories, to ensure it meets the specific needs of each environment.

Purchasing the D-Dimer Detection Kit requires careful consideration of various factors, including product specifications, types, budget, and intended use. By evaluating these aspects, you can ensure that the kit meets your clinical needs and provides reliable and accurate results in your specific setting.

 Precautions

Proper handling and storage of the D-Dimer Detection Kit are essential to ensure accurate results and maintain the integrity of the components.

1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the reagents and ensure consistent performance.
2. Handling Precautions: Follow proper laboratory safety protocols, including the use of personal protective equipment, to avoid contamination and ensure user safety.
3. Expiration Date: Always check the expiration date before use to ensure the kit's components are still effective.
4. Sample Handling: Ensure that blood samples are collected and processed according to the kit's instructions to avoid errors in D-dimer measurement.
5. Disposal: Dispose of used components according to biohazard waste disposal guidelines to prevent contamination and ensure environmental safety.

The D-Dimer Detection Kit requires careful handling and storage to maintain its performance and ensure accurate results. Adhering to proper storage conditions, handling precautions, and disposal guidelines is essential for both user safety and the reliability of the diagnostic outcomes.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files