Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Test Kit (Latex Immunoturbidimetric Method)
The D-Dimer Test Kit consists of two main reagents: Reagent ①, a Tris-HCl buffer (pH 8.5) at a concentration of 30mmol/L, and Reagent ②, latex particles coated with mouse anti-human D-Dimer monoclonal antibodies at a concentration of 2.8mg/mL. These components are designed to work together to provide accurate and reliable quantitative measurements of D-Dimer levels in human plasma.
Product English Name:
D-Dimer Test Kit (Latex Immunoturbidimetric Method)
Alias:
D-Dimer Assay Kit,D-Dimer Diagnostic Kit
Intended Use:
This kit is specifically designed for the in vitro quantitative detection of D-Dimer concentration in human plasma. It is widely used in clinical settings to aid in the diagnosis and monitoring of conditions such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation.
Product Introduction

The D-Dimer Test Kit (Latex Immunoturbidimetric Method) is a sophisticated diagnostic tool used to measure the concentration of D-Dimer in human plasma. D-Dimer is a fibrin degradation product that is typically elevated in conditions associated with blood clot formation and breakdown. This kit employs a latex immunoturbidimetric method, which is known for its high sensitivity and specificity, making it an essential tool in clinical laboratories.

1. The D-Dimer Test Kit is characterized by its high sensitivity and specificity, ensuring accurate detection of D-Dimer levels even at low concentrations. The use of latex particles coated with monoclonal antibodies enhances the precision of the assay.
2. The kit is composed of two main reagents: a Tris-HCl buffer and latex particles coated with mouse anti-human D-Dimer monoclonal antibodies. These components are carefully formulated to ensure stability and reliability during the assay process.
3. The primary use of this kit is to quantitatively measure D-Dimer levels in human plasma, which is crucial for diagnosing and monitoring thrombotic disorders. It is particularly useful in emergency settings where rapid and accurate diagnosis is essential.

The D-Dimer Test Kit, also known as the D-Dimer Assay Kit, is a vital diagnostic tool in the medical field. Its high sensitivity and specificity make it indispensable for detecting and monitoring conditions related to blood clot formation and breakdown. The kit's composition, including its specialized reagents, ensures reliable and accurate results, making it a trusted choice for clinicians and laboratory professionals.

Main Features

The D-Dimer Test Kit offers high sensitivity and specificity for the quantitative detection of D-Dimer in human plasma. Its latex immunoturbidimetric method ensures accurate and reliable results, making it a valuable tool in clinical diagnostics.

1. High Sensitivity: The kit is designed to detect even low concentrations of D-Dimer, ensuring accurate diagnosis of thrombotic disorders.
2. Specificity: The use of monoclonal antibodies ensures that the assay is highly specific to D-Dimer, reducing the risk of false positives.
3. Rapid Results: The latex immunoturbidimetric method allows for quick and efficient measurement of D-Dimer levels, which is crucial in emergency settings.
4. Stability: The reagents are formulated to maintain stability over time, ensuring consistent performance throughout the shelf life of the kit.
5. Ease of Use: The kit is designed for ease of use, with clear instructions and minimal preparation required, making it accessible for laboratory professionals.

The D-Dimer Test Kit stands out for its high sensitivity, specificity, and rapid results. Its ease of use and stability make it a reliable choice for clinical laboratories. The kit's ability to provide accurate and timely results is particularly valuable in diagnosing and monitoring thrombotic disorders, making it an essential tool in modern medicine.

Clinical Applications

The D-Dimer Test Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders such as deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation. Its high sensitivity and specificity make it a valuable tool in emergency and routine diagnostics.

1. Diagnosis of Deep Vein Thrombosis (DVT): The kit is used to measure D-Dimer levels, which are typically elevated in patients with DVT, aiding in the diagnosis of this condition.
2. Monitoring Pulmonary Embolism (PE): Elevated D-Dimer levels are also indicative of PE, and the kit is used to monitor patients suspected of having this condition.
3. Detection of Disseminated Intravascular Coagulation (DIC): The kit is used to detect DIC, a condition characterized by widespread blood clot formation and breakdown.
4. Routine Screening: The kit is also used in routine screening for thrombotic disorders, particularly in high-risk patients.
5. Emergency Diagnostics: In emergency settings, the kit provides rapid and accurate results, aiding in the timely diagnosis and treatment of thrombotic disorders.

The D-Dimer Test Kit is a versatile tool in clinical diagnostics, particularly for the diagnosis and monitoring of thrombotic disorders. Its high sensitivity and specificity make it invaluable in both routine and emergency settings. The kit's ability to provide rapid and accurate results ensures that patients receive timely and appropriate care, highlighting its importance in modern healthcare.

Purchasing Guide

When purchasing the D-Dimer Test Kit, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help you make an informed decision.

1. Product Specifications: Ensure that the kit meets the required specifications for sensitivity, specificity, and stability. Check the concentration of reagents and the shelf life of the product.
2. Product Types: There are different types of D-Dimer Test Kits available, including those for specific clinical applications. Choose the type that best suits your laboratory's needs.
3. Budget: Consider your budget when selecting a kit. While cost is an important factor, it should not compromise the quality and reliability of the product.
4. Intended Use: Determine the primary use of the kit, whether for routine screening, emergency diagnostics, or specific clinical applications. This will help you select the most appropriate product.

Purchasing the right D-Dimer Test Kit requires careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that you select a kit that meets your laboratory's needs and provides reliable and accurate results. This guide aims to assist you in making an informed decision, ensuring that you invest in a product that will serve your clinical and diagnostic requirements effectively.

 Precautions

When using the D-Dimer Test Kit, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the integrity of the reagents. This section outlines key precautions to consider.

1. Proper Storage: Store the kit at the recommended temperature to maintain the stability and effectiveness of the reagents. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Handle the reagents with care to avoid contamination. Use clean and sterile equipment when preparing and conducting the assay.
3. Expiration Date: Always check the expiration date before using the kit. Do not use expired reagents as they may yield inaccurate results.
4. Sample Preparation: Ensure that plasma samples are properly prepared and free from clots or hemolysis, as these can affect the accuracy of the assay.
5. Quality Control: Regularly perform quality control tests to ensure the kit is functioning correctly and providing accurate results.

Using the D-Dimer Test Kit requires attention to detail and adherence to proper handling and storage procedures. By following these precautions, you can ensure the accuracy and reliability of your results. Proper storage, careful handling, and regular quality control checks are essential to maintaining the integrity of the kit and achieving optimal performance. These precautions not only safeguard the quality of your diagnostics but also contribute to the overall success of your clinical and laboratory operations.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files