Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Test Kit (Dry Immunofluorescence Quantitative Method)
The D-Dimer Test Kit (Dry Immunofluorescence Quantitative Method) is composed of single-use test cards available in packs of 10, 25, 50, or 100, whole blood buffer, an SD card, and optional pipettes. Each test card consists of a test strip housed within a casing. The test strip includes a sample pad, a fluorescence pad coated with fluorescently labeled D-Dimer monoclonal antibody I, a chromatography membrane with D-Dimer capture monoclonal antibodies II and III in the test zone and rabbit anti-mouse IgG antibody in the control zone, absorbent paper, and a backing pad. The whole blood buffer is formulated with 20mM phosphate, 0.5% casein, and 0.1% Tween.
Product English Name:
D-Dimer Test Kit (Dry Immunofluorescence Quantitative Method)
Alias:
D-Dimer Assay Kit,D-Dimer Quantitative Kit
Intended Use:
This test kit is designed for the in vitro quantitative detection of D-Dimer levels in human plasma or whole blood. It is widely used in clinical settings to assess coagulation disorders, monitor thrombolytic therapy, and evaluate the risk of thrombotic events.
Product Introduction

The D-Dimer Test Kit (Dry Immunofluorescence Quantitative Method) is a cutting-edge diagnostic tool designed for the accurate and rapid quantification of D-Dimer levels in human blood. Utilizing advanced immunofluorescence technology, this kit provides reliable results essential for diagnosing and monitoring conditions related to blood clotting and fibrinolysis. Its user-friendly design and high sensitivity make it a preferred choice in clinical laboratories.

1. The kit features a unique dry immunofluorescence quantitative method, ensuring high sensitivity and specificity in detecting D-Dimer levels. This method minimizes the risk of cross-reactivity and provides consistent results across various sample types.
2. The test card's structure includes multiple layers, such as the sample pad, fluorescence pad, chromatography membrane, and absorbent paper, each playing a crucial role in the accurate detection of D-Dimer. The fluorescence pad, coated with monoclonal antibodies, ensures precise binding and detection of the target analyte.
3. The kit is primarily used for the quantitative detection of D-Dimer in plasma or whole blood, aiding in the diagnosis of deep vein thrombosis, pulmonary embolism, and disseminated intravascular coagulation. It is also valuable in monitoring the effectiveness of anticoagulant therapy.

The D-Dimer Test Kit, also known as the D-Dimer Assay Kit, is a sophisticated diagnostic tool that combines advanced immunofluorescence technology with a meticulously designed test card structure. Its primary use in detecting D-Dimer levels makes it indispensable in clinical settings for diagnosing and managing coagulation disorders.

Main Features

The D-Dimer Test Kit offers high sensitivity, specificity, and ease of use, making it an essential tool for clinical diagnostics. Its advanced immunofluorescence technology ensures accurate and reliable results.

1. High Sensitivity: The kit's immunofluorescence method detects even low concentrations of D-Dimer, ensuring accurate diagnosis of coagulation disorders.
2. Specificity: The use of monoclonal antibodies minimizes cross-reactivity, providing precise results.
3. User-Friendly Design: The single-use test cards and straightforward procedure make the kit easy to use in various clinical settings.
4. Rapid Results: The kit provides quick and reliable results, essential for timely diagnosis and treatment.
5. Versatility: Suitable for use with both plasma and whole blood samples, the kit offers flexibility in sample handling.

The D-Dimer Test Kit stands out for its high sensitivity, specificity, and user-friendly design. Its ability to provide rapid and accurate results makes it a valuable tool in clinical diagnostics, particularly in the management of coagulation disorders.

Clinical Applications

The D-Dimer Test Kit is widely used in clinical settings for diagnosing and monitoring conditions related to blood clotting and fibrinolysis, such as deep vein thrombosis and pulmonary embolism.

1. Diagnosis of Deep Vein Thrombosis (DVT): The kit is used to detect elevated D-Dimer levels, a key indicator of DVT.
2. Pulmonary Embolism (PE) Detection: It aids in the rapid diagnosis of PE by quantifying D-Dimer levels in blood samples.
3. Monitoring Thrombolytic Therapy: The kit is used to assess the effectiveness of anticoagulant treatments in patients with coagulation disorders.
4. Disseminated Intravascular Coagulation (DIC) Diagnosis: It helps in identifying DIC by measuring D-Dimer levels, which are typically elevated in this condition.
5. Risk Assessment: The kit is used to evaluate the risk of thrombotic events in patients undergoing surgery or with a history of coagulation disorders.

The D-Dimer Test Kit is a versatile diagnostic tool used in various clinical applications, from diagnosing deep vein thrombosis and pulmonary embolism to monitoring thrombolytic therapy. Its ability to provide accurate and rapid results makes it indispensable in managing coagulation-related conditions.

Purchasing Guide

When purchasing the D-Dimer Test Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical needs.

1. Product Specifications: Evaluate the kit's sensitivity, specificity, and compatibility with your laboratory equipment.
2. Product Types: Choose between different pack sizes (10, 25, 50, or 100 test cards) based on your laboratory's volume and needs.
3. Budget: Consider the cost per test and overall budget to ensure the kit is cost-effective for your institution.
4. Intended Use: Ensure the kit is suitable for your specific clinical applications, such as DVT diagnosis or thrombolytic therapy monitoring.

Purchasing the D-Dimer Test Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure the kit meets your clinical needs and provides reliable results.

 Precautions

Proper handling and storage of the D-Dimer Test Kit are essential to ensure accurate results and maintain the integrity of the components.

1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the reagents and test cards.
2. Handling: Follow the manufacturer's instructions for handling the test cards and buffer to avoid contamination.
3. Sample Preparation: Ensure blood samples are collected and processed correctly to obtain accurate D-Dimer levels.
4. Expiry Date: Always check the expiry date of the kit before use to ensure the reagents are effective.
5. Disposal: Dispose of used test cards and other components according to local regulations to prevent biohazard risks.

To ensure the accuracy and reliability of the D-Dimer Test Kit, it is crucial to follow proper storage, handling, and disposal procedures. Adhering to these precautions will help maintain the integrity of the kit and provide consistent results in clinical diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files