D-Dimer Test Strip (Lateral Flow Immunoassay)
The D-Dimer Test Strip (Lateral Flow Immunoassay) consists of a test strip and a 1×PBS buffer solution (3.5ml, pH 7.4) containing BSA. The test strip includes a nitrocellulose membrane with test and control lines, a conjugate pad with gold-labeled antibodies, a sample pad, an absorbent pad, and a backing card. The linear range of the dose-response curve is 500-5000 ng/ml, with a precision of CV≤15% and an accuracy of relative deviation ≤15.0%.
Product English Name:
D-Dimer Test Strip (Lateral Flow Immunoassay)
Alias:
D-Dimer Rapid Test,Thrombosis Diagnostic Strip
Intended Use:
This product is designed for the quantitative detection of D-Dimer levels in human whole blood, serum, and plasma. It aids in the diagnosis and treatment of thrombotic diseases such as venous thromboembolism, pulmonary embolism, and deep vein thrombosis.
Product Introduction

The D-Dimer Test Strip is a rapid, reliable, and easy-to-use diagnostic tool for detecting D-Dimer levels in blood samples. It employs a lateral flow immunoassay method, providing quick results with high accuracy. The test is particularly useful in clinical settings for assessing thrombotic conditions and monitoring treatment efficacy.

1. The test strip features a nitrocellulose membrane with specific antibodies for D-Dimer detection, ensuring high sensitivity and specificity.
2. The strip's design includes multiple layers, such as a conjugate pad with gold-labeled antibodies, a sample pad for blood application, and an absorbent pad to facilitate fluid flow, ensuring consistent and reliable results.
3. The test is used to quantitatively measure D-Dimer levels, aiding in the diagnosis of thrombotic diseases and helping clinicians make informed decisions about patient care.

The D-Dimer Test Strip, also known as the D-Dimer Rapid Test, is a vital tool in modern medicine. Its precise design and reliable performance make it indispensable for diagnosing and managing thrombotic conditions. Whether in a hospital or a clinic, this test strip provides quick and accurate results, helping healthcare professionals save lives.

Main Features

The D-Dimer Test Strip offers rapid and accurate detection of D-Dimer levels, making it an essential tool for diagnosing thrombotic diseases. Its user-friendly design ensures ease of use in various clinical settings.

1. High sensitivity and specificity due to the use of specific antibodies on the nitrocellulose membrane.
2. The lateral flow immunoassay method ensures quick results, typically within minutes.
3. The test strip is designed for ease of use, requiring only a small blood sample and minimal preparation.
4. The product's linear range and precision make it suitable for both qualitative and quantitative analysis.
5. The test strip is compatible with whole blood, serum, and plasma, providing flexibility in sample collection.

The D-Dimer Test Strip is a versatile and reliable diagnostic tool. Its main features, including high sensitivity, rapid results, and ease of use, make it a preferred choice for healthcare professionals. Whether used in emergency rooms or routine check-ups, this test strip delivers consistent and accurate results.

Clinical Applications

The D-Dimer Test Strip is widely used in clinical settings to diagnose and monitor thrombotic diseases. Its rapid results and high accuracy make it a valuable tool for healthcare providers.

1. The test strip is used in emergency rooms to quickly assess patients with suspected pulmonary embolism or deep vein thrombosis.
2. It is employed in outpatient clinics for routine monitoring of patients on anticoagulant therapy.
3. The test is used in research settings to study the efficacy of new treatments for thrombotic diseases.
4. It is also used in diagnostic laboratories for high-throughput screening of blood samples.
5. The test strip is valuable in telemedicine, allowing remote diagnosis and monitoring of patients with thrombotic conditions.

The D-Dimer Test Strip has a wide range of clinical applications, from emergency diagnostics to routine patient monitoring. Its rapid and accurate results make it an indispensable tool for healthcare providers, helping them make informed decisions and improve patient outcomes.

Purchasing Guide

When purchasing the D-Dimer Test Strip, consider factors such as product specifications, types, budget, and intended use to ensure you select the right product for your needs.

1. Product specifications: Ensure the test strip meets your required sensitivity, specificity, and linear range for accurate results.
2. Product types: Choose between different formats, such as single-use strips or multi-test kits, based on your testing volume.
3. Budget: Consider the cost per test and overall budget to ensure the product is cost-effective for your facility.
4. Usage scenarios: Evaluate the test strip's compatibility with your sample types (whole blood, serum, plasma) and testing environment (hospital, clinic, lab).

Purchasing the D-Dimer Test Strip requires careful consideration of various factors, including product specifications, types, budget, and usage scenarios. By taking these factors into account, you can ensure that you select the right product to meet your diagnostic needs and improve patient care.

 Precautions

Proper handling and storage of the D-Dimer Test Strip are essential to ensure accurate results and maintain product integrity.

1. Store the test strips in a cool, dry place, away from direct sunlight and moisture, to prevent degradation.
2. Follow the manufacturer's instructions for sample collection and application to avoid contamination and ensure accurate results.
3. Use the test strips within their expiration date to maintain reliability and accuracy.
4. Dispose of used test strips and biohazard materials according to local regulations to ensure safety and compliance.
5. Regularly calibrate and maintain any equipment used in conjunction with the test strips to ensure consistent performance.

Handling the D-Dimer Test Strip with care is crucial for obtaining reliable results. Proper storage, usage, and disposal practices not only ensure the accuracy of the test but also maintain a safe and compliant laboratory environment. By following these precautions, healthcare providers can confidently rely on the test strip for accurate diagnostics.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files