Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Test Kit (Colloidal Gold Method)
The D-Dimer Test Kit is composed of a reagent card, a graduated dropper (optional, made of LDPE, capable of dispensing 10 or 15 microliters), a sample dilution tube (containing sample diluent, 1.5ml per bottle), and a desiccant (silica gel). The reagent card consists of a test strip and a card shell. The test strip includes a colloidal gold pad (containing colloidal gold-labeled mouse anti-D-Dimer monoclonal antibody 2), a nitrocellulose membrane (with mouse anti-D-Dimer monoclonal antibody 1 fixed on the T line and goat anti-mouse IgG antibody fixed on the C line), and other supporting materials such as a sample pad (glass fiber), absorbent paper, and a PVC backing. The sample diluent is 20mM PBS containing Casein, EDTA, and Proclin300.
Product English Name:
D-Dimer Test Kit (Colloidal Gold Method)
Alias:
D-Dimer Rapid Test Kit,D-Dimer Assay Kit
Intended Use:
This product is used for the qualitative detection of D-Dimer levels in human plasma and whole blood in vitro.
Product Introduction

The D-Dimer Test Kit (Colloidal Gold Method) is a rapid diagnostic tool designed for the qualitative detection of D-Dimer levels in human plasma and whole blood. It is widely used in clinical settings to aid in the diagnosis of conditions such as deep vein thrombosis (DVT), pulmonary embolism (PE), and disseminated intravascular coagulation (DIC). The kit is known for its ease of use, quick results, and high sensitivity.

1. The D-Dimer Test Kit is characterized by its high sensitivity and specificity, making it a reliable tool for detecting D-Dimer levels. The colloidal gold method ensures rapid and accurate results, which are crucial in emergency medical situations.
2. The kit is composed of several key components, including a reagent card, a graduated dropper, a sample dilution tube, and a desiccant. The reagent card contains a test strip with a colloidal gold pad, a nitrocellulose membrane, and other supporting materials that facilitate the detection process.
3. The primary use of the D-Dimer Test Kit is for the qualitative detection of D-Dimer levels in human plasma and whole blood. It is particularly useful in diagnosing conditions related to blood clotting disorders, such as DVT, PE, and DIC.

The D-Dimer Test Kit, also known as the D-Dimer Rapid Test Kit, is a vital tool in the medical field for detecting D-Dimer levels. Its high sensitivity and specificity, combined with its ease of use, make it an essential component in diagnosing blood clotting disorders. The kit's composition, including the reagent card and sample diluent, ensures accurate and reliable results, making it a trusted choice for healthcare professionals.

Main Features

The D-Dimer Test Kit offers rapid and accurate detection of D-Dimer levels, making it an essential tool in diagnosing blood clotting disorders. Its high sensitivity and specificity ensure reliable results, while its ease of use makes it suitable for various clinical settings.

1. The D-Dimer Test Kit provides rapid results, typically within minutes, which is crucial in emergency medical situations where timely diagnosis is essential.
2. The kit's high sensitivity ensures that even low levels of D-Dimer can be detected, reducing the risk of false negatives and improving diagnostic accuracy.
3. The specificity of the kit ensures that it accurately detects D-Dimer without cross-reacting with other substances, providing reliable results for healthcare professionals.
4. The ease of use of the D-Dimer Test Kit makes it suitable for use in various clinical settings, including hospitals, clinics, and laboratories. The simple procedure requires minimal training, allowing for widespread adoption.
5. The kit's stability and long shelf life ensure that it remains effective over time, reducing the need for frequent replacements and ensuring consistent performance.

The D-Dimer Test Kit is a reliable and efficient tool for detecting D-Dimer levels. Its rapid results, high sensitivity, and specificity make it an essential component in diagnosing blood clotting disorders. The kit's ease of use and stability further enhance its appeal, making it a trusted choice for healthcare professionals in various clinical settings.

Clinical Applications

The D-Dimer Test Kit is widely used in clinical settings to aid in the diagnosis of conditions such as deep vein thrombosis (DVT), pulmonary embolism (PE), and disseminated intravascular coagulation (DIC). Its rapid and accurate results make it an essential tool for healthcare professionals.

1. The D-Dimer Test Kit is commonly used in emergency rooms to quickly diagnose conditions such as DVT and PE, where timely intervention is critical.
2. In outpatient clinics, the kit is used to monitor patients with a history of blood clotting disorders, providing quick and reliable results that guide treatment decisions.
3. The kit is also used in laboratories for research purposes, where its high sensitivity and specificity make it a valuable tool for studying blood clotting mechanisms.
4. In surgical settings, the D-Dimer Test Kit is used to assess the risk of postoperative blood clotting, helping to prevent complications such as DVT and PE.
5. The kit is also used in general practice settings to screen patients for blood clotting disorders, providing a quick and easy way to identify potential issues.

The D-Dimer Test Kit is a versatile tool used in various clinical settings to diagnose and monitor blood clotting disorders. Its rapid and accurate results make it an essential component in emergency rooms, outpatient clinics, laboratories, and surgical settings. The kit's reliability and ease of use ensure that it remains a trusted choice for healthcare professionals.

Purchasing Guide

When purchasing the D-Dimer Test Kit, it is important to consider factors such as product specifications, types, budget, and usage scenarios to ensure that the kit meets your specific needs.

1. Product specifications: Ensure that the kit includes all necessary components, such as the reagent card, graduated dropper, sample dilution tube, and desiccant. Verify the specifications of each component to ensure compatibility with your clinical needs.
2. Product types: Consider the different types of D-Dimer Test Kits available, such as those designed for specific sample types (plasma or whole blood) or those with different sensitivity levels. Choose the type that best suits your diagnostic requirements.
3. Budget: Determine your budget for the D-Dimer Test Kit, taking into account the cost per test and the overall value provided by the kit. Consider the long-term cost-effectiveness of the kit, including its shelf life and stability.
4. Usage scenarios: Evaluate the specific scenarios in which the kit will be used, such as emergency rooms, outpatient clinics, or laboratories. Ensure that the kit's features, such as rapid results and ease of use, align with the demands of your clinical setting.

Purchasing the D-Dimer Test Kit requires careful consideration of product specifications, types, budget, and usage scenarios. By evaluating these factors, you can ensure that the kit meets your specific clinical needs and provides reliable and accurate results. The kit's versatility and ease of use make it a valuable addition to any healthcare setting.

 Precautions

When using the D-Dimer Test Kit, it is important to follow proper procedures and precautions to ensure accurate results and maintain safety.

1. Always wear appropriate personal protective equipment (PPE), such as gloves and lab coats, when handling the kit to prevent contamination and ensure safety.
2. Follow the manufacturer's instructions carefully when using the kit, including proper storage conditions and handling procedures, to ensure accurate and reliable results.
3. Ensure that all components of the kit are within their expiration dates and have been stored correctly to maintain their effectiveness.
4. Dispose of used components, such as the reagent card and sample dilution tube, in accordance with biohazard waste disposal guidelines to prevent contamination and ensure safety.
5. Regularly calibrate and maintain any equipment used in conjunction with the D-Dimer Test Kit, such as pipettes and centrifuges, to ensure accurate and consistent results.

Using the D-Dimer Test Kit requires adherence to proper procedures and precautions to ensure accurate results and maintain safety. By following the manufacturer's instructions, wearing appropriate PPE, and properly disposing of used components, you can ensure the reliability and safety of the kit. Regular maintenance of associated equipment further enhances the accuracy and consistency of the results.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files