Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
D-Dimer Detection Kit (Time-Resolved Fluorescence Immunochromatography)
The D-Dimer Detection Kit is designed for the quantitative measurement of D-Dimer levels in human plasma. It utilizes time-resolved fluorescence immunochromatography, a highly sensitive and specific method for detecting biomarkers. The kit includes all necessary reagents and components for accurate and reliable testing, ensuring consistent results in clinical and laboratory settings.
Product English Name:
D-Dimer Detection Kit (Time-Resolved Fluorescence Immunochromatography)
Alias:
D-Dimer Test Kit,Fluorescence Immunoassay Kit
Intended Use:
This kit is primarily used for the quantitative detection of D-Dimer levels in human plasma. D-Dimer is a fibrin degradation product, and its elevated levels are often associated with thrombotic disorders such as deep vein thrombosis (DVT), pulmonary embolism (PE), and disseminated intravascular coagulation (DIC). The kit aids in the diagnosis and monitoring of these conditions, providing critical information for patient management.
Product Introduction

The D-Dimer Detection Kit is a state-of-the-art diagnostic tool designed for the quantitative measurement of D-Dimer levels in human plasma. Utilizing time-resolved fluorescence immunochromatography, this kit offers high sensitivity and specificity, making it an essential tool in the diagnosis and monitoring of thrombotic disorders. The kit is easy to use, with a straightforward procedure that ensures quick and accurate results, making it suitable for both clinical and laboratory settings.

1. The D-Dimer Detection Kit is characterized by its high sensitivity and specificity, ensuring accurate detection of D-Dimer levels even at low concentrations. The use of time-resolved fluorescence immunochromatography enhances the precision of the results, making it a reliable tool for clinical diagnostics.
2. The kit is composed of several key components, including specific antibodies, fluorescent labels, and a solid-phase support. These components work together to capture and quantify D-Dimer in plasma samples. The design ensures minimal cross-reactivity and high reproducibility, which are crucial for consistent and reliable results.
3. The primary use of the D-Dimer Detection Kit is in the diagnosis and monitoring of thrombotic disorders such as deep vein thrombosis (DVT), pulmonary embolism (PE), and disseminated intravascular coagulation (DIC). By providing accurate and timely results, the kit aids healthcare professionals in making informed decisions regarding patient care and treatment.

The D-Dimer Detection Kit, also known as the Fluorescence Immunoassay Kit, is a vital tool in the diagnosis and monitoring of thrombotic disorders. Its high sensitivity and specificity, combined with a straightforward procedure, make it an indispensable resource for healthcare professionals. Whether in a clinical or laboratory setting, this kit provides reliable and accurate results, ensuring optimal patient care.

Main Features

The D-Dimer Detection Kit offers high sensitivity and specificity, utilizing time-resolved fluorescence immunochromatography for accurate D-Dimer measurement. It is designed for ease of use, providing quick and reliable results in clinical and laboratory settings.

1. The kit employs time-resolved fluorescence immunochromatography, a highly sensitive and specific method for detecting D-Dimer levels in plasma. This technology ensures accurate results even at low concentrations, making it ideal for early diagnosis of thrombotic disorders.
2. The kit includes all necessary reagents and components, such as specific antibodies and fluorescent labels, which work together to capture and quantify D-Dimer. The design minimizes cross-reactivity and ensures high reproducibility, providing consistent results across different samples.
3. The procedure is straightforward and user-friendly, requiring minimal training. This makes the kit suitable for use in various settings, including hospitals, clinics, and research laboratories, where quick and accurate results are essential.
4. The kit is designed for high-throughput testing, allowing for the simultaneous analysis of multiple samples. This feature is particularly beneficial in busy clinical environments where time is of the essence.
5. The results obtained from the kit are highly reliable and can be used to guide clinical decisions. The accuracy and precision of the kit make it a valuable tool for the diagnosis and monitoring of thrombotic disorders, ensuring optimal patient outcomes.

The D-Dimer Detection Kit is a powerful diagnostic tool that combines high sensitivity, specificity, and ease of use. Its advanced technology and user-friendly design make it an essential resource for healthcare professionals, providing reliable and accurate results that are crucial for patient care.

Clinical Applications

The D-Dimer Detection Kit is widely used in clinical settings for the diagnosis and monitoring of thrombotic disorders. Its high sensitivity and specificity make it an invaluable tool for healthcare professionals.

1. The kit is commonly used in the diagnosis of deep vein thrombosis (DVT), a condition characterized by the formation of blood clots in deep veins. Accurate detection of D-Dimer levels helps in the early diagnosis and management of DVT, reducing the risk of complications.
2. Pulmonary embolism (PE), a potentially life-threatening condition caused by blood clots in the lungs, is another key application of the kit. By measuring D-Dimer levels, healthcare professionals can quickly assess the likelihood of PE and initiate appropriate treatment.
3. The kit is also used in the diagnosis and monitoring of disseminated intravascular coagulation (DIC), a complex condition involving widespread blood clotting and bleeding. Accurate D-Dimer measurement is crucial for managing DIC and preventing further complications.
4. In addition to thrombotic disorders, the kit is used in the assessment of other conditions associated with elevated D-Dimer levels, such as sepsis, trauma, and certain cancers. This broad applicability makes the kit a versatile tool in clinical diagnostics.
5. The kit is also valuable in research settings, where it is used to study the role of D-Dimer in various diseases and conditions. Its high sensitivity and specificity make it an ideal tool for investigating the mechanisms underlying thrombotic disorders and developing new treatments.

The D-Dimer Detection Kit is a versatile and essential tool in clinical diagnostics, widely used for the diagnosis and monitoring of thrombotic disorders. Its high sensitivity and specificity, combined with its broad applicability, make it an invaluable resource for healthcare professionals and researchers alike.

Purchasing Guide

When purchasing the D-Dimer Detection Kit, it is important to consider factors such as product specifications, types, budget, and intended use. This guide provides essential information to help you make an informed decision.

1. Product specifications: Ensure that the kit meets your specific requirements, including sensitivity, specificity, and detection range. The kit should be compatible with your laboratory equipment and procedures.
2. Product types: There are different types of D-Dimer Detection Kits available, each with its own set of features and applications. Choose the one that best suits your needs, whether for clinical diagnostics or research purposes.
3. Budget: Consider your budget when selecting a kit. While cost is an important factor, it should not compromise the quality and reliability of the kit. Look for a balance between cost and performance.
4. Intended use: Determine the primary use of the kit, whether for routine clinical testing, research, or high-throughput analysis. This will help you select a kit that is optimized for your specific application.

Purchasing the right D-Dimer Detection Kit requires careful consideration of various factors, including product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that you select a kit that meets your needs and provides reliable and accurate results.

 Precautions

Proper handling and storage of the D-Dimer Detection Kit are essential to ensure accurate and reliable results. This section outlines key precautions to follow when using the kit.

1. Storage: Store the kit at the recommended temperature to maintain the stability and effectiveness of the reagents. Avoid exposure to extreme temperatures and direct sunlight.
2. Handling: Follow the manufacturer's instructions for handling the kit components. Use appropriate personal protective equipment (PPE) to prevent contamination and ensure safety.
3. Sample preparation: Ensure that plasma samples are collected and prepared correctly. Improper sample handling can lead to inaccurate results.
4. Calibration: Regularly calibrate the equipment used with the kit to ensure accurate measurements. Follow the calibration procedures provided by the manufacturer.
5. Disposal: Dispose of used kit components and samples in accordance with local regulations and guidelines. Proper disposal is essential to prevent contamination and ensure safety.

Following the recommended precautions when using the D-Dimer Detection Kit is crucial for obtaining accurate and reliable results. Proper storage, handling, sample preparation, calibration, and disposal are key to ensuring the effectiveness and safety of the kit.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files