C-Reactive Protein (CRP) Control Material
The CRP Control Material consists of two components: Control 1 and Control 2. Control 1 contains Tris buffer, Proclin300, sodium chloride, bovine serum albumin, and CRP antigen with a target concentration range of 16.0-24.0 mg/L. Control 2 contains the same components but with a target concentration range of 32.0-48.0 mg/L. These materials are designed for use in quality control procedures for CRP testing.
Product English Name:
C-Reactive Protein (CRP) Control Material
Alias:
CRP Control,CRP Quality Control
Intended Use:
This product is specifically designed for indoor quality control of C-reactive protein (CRP) testing using specific protein analyzers from Shenzhen Guosai Biotechnology Co., Ltd. It ensures the accuracy and reliability of CRP measurements in clinical settings.
Product Introduction

The C-Reactive Protein (CRP) Control Material is a high-quality product designed for use in clinical laboratories to ensure the accuracy and reliability of CRP testing. It is composed of carefully calibrated components that mimic human serum, making it an essential tool for quality control in CRP analysis.

1. The CRP Control Material is characterized by its high stability and consistency, ensuring reliable results over time. It is designed to mimic human serum, providing a realistic environment for testing.
2. The composition of the CRP Control Material includes Tris buffer, Proclin300, sodium chloride, bovine serum albumin, and CRP antigen. These components are carefully balanced to achieve the desired concentration ranges of 16.0-24.0 mg/L and 32.0-48.0 mg/L.
3. The primary use of the CRP Control Material is for indoor quality control in CRP testing. It is specifically designed for use with specific protein analyzers from Shenzhen Guosai Biotechnology Co., Ltd., ensuring accurate and reliable CRP measurements.

The CRP Control Material is a vital tool for ensuring the accuracy of CRP testing in clinical laboratories. Its carefully calibrated composition and high stability make it an essential component of any quality control program. Whether you're a seasoned lab technician or a new researcher, this product will help you achieve reliable and consistent results.

Main Features

The CRP Control Material offers high stability, consistency, and accuracy, making it an essential tool for quality control in CRP testing.

1. High Stability: The CRP Control Material is designed to maintain its stability over time, ensuring consistent results even after prolonged storage.
2. Consistent Performance: The carefully calibrated components ensure that the material performs consistently across different batches, providing reliable results every time.
3. Accurate Concentration: The target concentration ranges of 16.0-24.0 mg/L and 32.0-48.0 mg/L are precisely achieved, ensuring accurate CRP measurements.
4. Mimics Human Serum: The composition of the CRP Control Material closely mimics human serum, providing a realistic environment for testing.
5. Easy to Use: The material is designed for easy integration into existing quality control procedures, making it simple to use in any clinical laboratory.

The CRP Control Material is a reliable and consistent tool for quality control in CRP testing. Its high stability, accurate concentration, and ease of use make it an essential component of any clinical laboratory. Whether you're conducting routine tests or complex research, this product will help you achieve accurate and reliable results.

Clinical Applications

The CRP Control Material is widely used in clinical laboratories for quality control in CRP testing, ensuring accurate and reliable results.

1. Routine Testing: The CRP Control Material is used in routine CRP testing to ensure the accuracy and reliability of results.
2. Research: Researchers use the CRP Control Material to validate new testing methods and ensure the consistency of their results.
3. Quality Assurance: Clinical laboratories use the CRP Control Material as part of their quality assurance programs to maintain high standards of testing.
4. Training: The material is also used in training programs to help new technicians learn the proper procedures for CRP testing.
5. Regulatory Compliance: The CRP Control Material helps laboratories comply with regulatory requirements by providing a reliable tool for quality control.

The CRP Control Material is an essential tool for clinical laboratories, ensuring accurate and reliable CRP testing. Its use in routine testing, research, quality assurance, training, and regulatory compliance makes it a versatile and valuable product for any laboratory.

Purchasing Guide

When purchasing the CRP Control Material, consider product parameters, types, budget, and usage scenarios to ensure you select the right product for your needs.

1. Product Parameters: Consider the concentration ranges, stability, and composition of the CRP Control Material to ensure it meets your testing requirements.
2. Product Types: Choose between different types of CRP Control Materials based on your specific testing needs and the equipment you use.
3. Budget: Determine your budget and compare prices from different suppliers to find the best value for your money.
4. Usage Scenarios: Consider the specific scenarios in which you will use the CRP Control Material, such as routine testing, research, or training, to ensure you select the right product.

Purchasing the CRP Control Material requires careful consideration of product parameters, types, budget, and usage scenarios. By taking these factors into account, you can ensure that you select the right product for your needs and achieve accurate and reliable CRP testing results.

 Precautions

When using the CRP Control Material, it is important to follow proper handling and storage procedures to ensure accurate and reliable results.

1. Storage: Store the CRP Control Material at the recommended temperature to maintain its stability and performance.
2. Handling: Handle the material with care to avoid contamination and ensure accurate results.
3. Usage: Follow the manufacturer's instructions for use to ensure proper integration into your quality control procedures.
4. Disposal: Dispose of the material according to local regulations to ensure safety and compliance.
5. Monitoring: Regularly monitor the performance of the CRP Control Material to ensure it continues to meet your quality control standards.

Proper handling, storage, and usage of the CRP Control Material are essential for achieving accurate and reliable results. By following the recommended procedures and regularly monitoring its performance, you can ensure that your CRP testing remains consistent and reliable.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files