The SelexOn CRP Assay Kit is a state-of-the-art diagnostic tool designed for accurate and rapid quantification of C-reactive protein (CRP) in human blood. Utilizing the colloidal gold method, this kit offers high sensitivity and specificity, making it an essential tool for clinical laboratories and healthcare providers. Its user-friendly design ensures ease of use, while the inclusion of an RFID tag enhances traceability and quality control.
1. The SelexOn CRP Assay Kit is characterized by its high sensitivity and specificity, ensuring reliable detection of CRP levels even at low concentrations. The colloidal gold method provides rapid results, making it ideal for urgent clinical scenarios.
2. The kit comprises test strips with multiple layers of antibodies, including anti-CRP monoclonal antibodies and gold-labeled antibodies, ensuring precise binding and detection. The dilution tubes contain a phosphate buffer to maintain sample integrity during testing.
3. This kit is primarily used for diagnosing and monitoring inflammatory conditions, infections, and cardiovascular diseases. Its quantitative results aid in clinical decision-making and patient management.
The SelexOn CRP Assay Kit, also known as the CRP Test Kit, is a reliable and efficient tool for measuring CRP levels in blood. Its advanced design and high accuracy make it a preferred choice for healthcare professionals. Whether you're monitoring inflammation or assessing cardiovascular risks, this kit delivers consistent and trustworthy results.
The SelexOn CRP Assay Kit offers high sensitivity, rapid results, and ease of use, making it a versatile tool for clinical diagnostics.
1. High Sensitivity: The kit detects CRP levels with exceptional accuracy, even at low concentrations, ensuring reliable results.
2. Rapid Results: Utilizing the colloidal gold method, the kit provides quick and precise readings, ideal for time-sensitive clinical situations.
3. User-Friendly Design: The kit is designed for ease of use, with clear instructions and minimal preparation required.
4. Traceability: The inclusion of an RFID tag ensures product traceability and enhances quality control.
5. Versatility: Suitable for a wide range of clinical applications, including inflammation monitoring and cardiovascular risk assessment.
The SelexOn CRP Assay Kit stands out for its high sensitivity, rapid results, and user-friendly design. Its advanced features make it an indispensable tool for clinical diagnostics, offering reliable and accurate CRP measurements.
The SelexOn CRP Assay Kit is widely used in clinical settings to diagnose and monitor inflammatory conditions, infections, and cardiovascular diseases.
1. Inflammation Monitoring: The kit is used to assess CRP levels, aiding in the diagnosis and management of inflammatory conditions such as rheumatoid arthritis and lupus.
2. Infection Detection: Elevated CRP levels are indicative of infections, making this kit valuable for diagnosing bacterial and viral infections.
3. Cardiovascular Risk Assessment: CRP is a marker for cardiovascular diseases, and this kit helps in evaluating patients' risk levels.
4. Post-Surgical Monitoring: The kit is used to monitor CRP levels post-surgery to detect complications such as infections or inflammation.
5. Chronic Disease Management: It aids in managing chronic conditions like diabetes and obesity by monitoring inflammation markers.
The SelexOn CRP Assay Kit is a versatile tool in clinical practice, offering valuable insights into inflammation, infections, and cardiovascular risks. Its applications extend from diagnosis to ongoing patient management, making it a cornerstone in modern healthcare.
This guide provides essential information for purchasing the SelexOn CRP Assay Kit, including product specifications, types, budget considerations, and usage scenarios.
1. Product Specifications: Ensure the kit meets your laboratory's requirements, including sensitivity, accuracy, and compatibility with existing equipment.
2. Product Types: Choose between different kit sizes or configurations based on your testing volume and clinical needs.
3. Budget Considerations: Evaluate the cost-effectiveness of the kit, considering its features, reliability, and long-term benefits.
4. Usage Scenarios: Assess the kit's suitability for your specific clinical applications, such as inflammation monitoring or infection detection.
Purchasing the SelexOn CRP Assay Kit requires careful consideration of specifications, types, and budget. Its versatility and reliability make it a worthwhile investment for clinical laboratories.
Proper handling and usage of the SelexOn CRP Assay Kit are essential to ensure accurate results and user safety.
1. Storage Conditions: Store the kit at the recommended temperature to maintain its efficacy and prevent degradation of components.
2. Sample Handling: Ensure blood samples are collected and processed correctly to avoid contamination or inaccurate results.
3. Expiry Date: Always check the kit's expiration date before use to ensure reliability.
4. User Training: Proper training is required for laboratory personnel to handle the kit and interpret results accurately.
5. Disposal: Follow local regulations for the disposal of used test strips and other kit components to ensure safety and environmental compliance.
Using the SelexOn CRP Assay Kit requires attention to storage, sample handling, and disposal. Proper training and adherence to guidelines ensure accurate results and a safe working environment.
We have the latest medical device product database in China, which can quickly meet your procurement needs.