C-Reactive Protein (CRP) / Serum Amyloid A (SAA) Combined Test Kit (Fluorescence Immunochromatography)
The product consists of a test card, sample buffer, ID chip, and optional quality control materials. The test card includes a test strip and a plastic casing. The test strip is composed of a nitrocellulose membrane, sample pad, absorbent paper, and PVC backing. The nitrocellulose membrane is coated with mouse anti-human CRP monoclonal antibody, mouse anti-human SAA monoclonal antibody, rabbit IgG, fluorescent-labeled mouse anti-human CRP monoclonal antibody, mouse anti-human SAA monoclonal antibody, and fluorescent-labeled goat anti-rabbit IgG. The sample buffer is primarily PBS buffer containing 0.1% Triton X-100 surfactant. The optional quality control materials include CRP, SAA, and PBS buffer.
Product English Name:
C-Reactive Protein (CRP) / Serum Amyloid A (SAA) Combined Test Kit (Fluorescence Immunochromatography)
Alias:
CRP/SAA Test Kit,Fluorescence Immunoassay Kit
Intended Use:
This kit is designed for the quantitative detection of C-reactive protein (CRP) and serum amyloid A (SAA) concentrations in human serum. It serves as a non-specific inflammatory marker, aiding in the assessment of inflammatory conditions and monitoring disease progression.
Product Introduction

The C-Reactive Protein (CRP) / Serum Amyloid A (SAA) Combined Test Kit is a state-of-the-art diagnostic tool utilizing fluorescence immunochromatography for the simultaneous detection of CRP and SAA in human serum. This kit is essential for clinicians to evaluate inflammatory responses and monitor patient health effectively.

1. The kit features a highly sensitive and specific detection method, ensuring accurate measurement of CRP and SAA levels. The fluorescence immunochromatography technique provides rapid results with minimal sample preparation.
2. The test card is composed of a nitrocellulose membrane, sample pad, absorbent paper, and PVC backing. The membrane is coated with specific antibodies and fluorescent markers, enabling precise detection of target proteins.
3. This kit is primarily used in clinical settings to assess inflammatory conditions, monitor disease progression, and evaluate the effectiveness of treatments. It is a valuable tool for healthcare professionals in managing patient care.

The CRP/SAA Combined Test Kit is a reliable and efficient diagnostic tool that combines advanced fluorescence immunochromatography with a well-designed test card structure. Its ability to simultaneously detect CRP and SAA makes it indispensable in clinical settings for monitoring inflammatory conditions and guiding treatment decisions.

Main Features

The CRP/SAA Combined Test Kit offers high sensitivity, specificity, and rapid results, making it an essential tool for clinical diagnostics.

1. High Sensitivity: The kit can detect low concentrations of CRP and SAA, ensuring accurate results even in early stages of inflammation.
2. Specificity: The use of monoclonal antibodies ensures that the kit specifically targets CRP and SAA, reducing the risk of cross-reactivity.
3. Rapid Results: The fluorescence immunochromatography method provides results within minutes, allowing for quick clinical decision-making.
4. User-Friendly: The kit is designed for ease of use, with minimal sample preparation required.
5. Versatility: Suitable for use in various clinical settings, including hospitals, clinics, and research laboratories.

The CRP/SAA Combined Test Kit stands out for its high sensitivity, specificity, and rapid results. Its user-friendly design and versatility make it a valuable asset in clinical diagnostics, providing healthcare professionals with reliable tools for patient care.

Clinical Applications

The CRP/SAA Combined Test Kit is widely used in clinical settings to assess inflammatory conditions, monitor disease progression, and evaluate treatment effectiveness.

1. Inflammatory Conditions: The kit is used to diagnose and monitor conditions such as rheumatoid arthritis, lupus, and other autoimmune diseases.
2. Infection Monitoring: It helps in detecting and monitoring bacterial and viral infections by measuring CRP and SAA levels.
3. Cardiovascular Risk Assessment: Elevated CRP levels are associated with increased cardiovascular risk, making this kit useful in risk assessment.
4. Post-Surgical Monitoring: The kit is used to monitor patients post-surgery to detect any signs of infection or inflammation.
5. Research Applications: It is also used in research studies to understand the role of CRP and SAA in various diseases.

The CRP/SAA Combined Test Kit is a versatile tool in clinical practice, aiding in the diagnosis and monitoring of inflammatory conditions, infections, and cardiovascular risks. Its application extends to post-surgical monitoring and research, making it an indispensable resource for healthcare professionals.

Purchasing Guide

This guide provides essential information for purchasing the CRP/SAA Combined Test Kit, including product specifications, types, budget considerations, and usage scenarios.

1. Product Specifications: Ensure the kit meets your laboratory's requirements, including sensitivity, specificity, and detection range.
2. Product Types: Choose between different kit formats, such as single-use or multi-use, based on your laboratory's needs.
3. Budget Considerations: Evaluate the cost-effectiveness of the kit, considering factors like shelf life, storage requirements, and additional accessories.
4. Usage Scenarios: Consider the clinical settings where the kit will be used, such as hospitals, clinics, or research laboratories, to ensure it meets the specific needs of your practice.

Purchasing the CRP/SAA Combined Test Kit requires careful consideration of product specifications, types, budget, and usage scenarios. By evaluating these factors, you can ensure that the kit meets your laboratory's needs and provides reliable results for patient care.

 Precautions

Proper handling and usage of the CRP/SAA Combined Test Kit are crucial to ensure accurate results and maintain safety.

1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability of the reagents.
2. Sample Handling: Ensure that serum samples are collected and processed correctly to avoid contamination or degradation.
3. Reagent Preparation: Follow the manufacturer's instructions for preparing and using reagents to ensure accurate results.
4. Disposal: Dispose of used test cards and reagents according to local regulations to prevent environmental contamination.
5. Training: Ensure that all personnel using the kit are properly trained in its handling and interpretation of results.

Adhering to proper storage, handling, and disposal procedures is essential for the accurate and safe use of the CRP/SAA Combined Test Kit. Proper training of personnel and careful attention to sample handling and reagent preparation will ensure reliable results and maintain a safe laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files