Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
C-Reactive Protein (CRP) / Serum Amyloid A (SAA) Assay Kit (Immunofluorescence Chromatography)
The kit primarily consists of a test card, sample buffer, and an information card. The test card includes a fluorescence pad coated with fluorescent-labeled CRP and SAA monoclonal mouse antibodies, a nitrocellulose membrane coated with CRP and SAA monoclonal mouse antibodies, absorbent paper, and a PVC backing. The sample buffer is mainly composed of phosphate buffer. The information card records the standard curve information for the batch of reagents.
Product English Name:
C-Reactive Protein (CRP) / Serum Amyloid A (SAA) Assay Kit (Immunofluorescence Chromatography)
Alias:
CRP/SAA Test Kit,Inflammation Marker Kit
Intended Use:
This kit is used for the quantitative detection of C-reactive protein (CRP) and serum amyloid A (SAA) in human serum, plasma, and whole blood samples. Both CRP and SAA are primarily used as non-specific markers of inflammation.
Product Introduction

The C-Reactive Protein (CRP) / Serum Amyloid A (SAA) Assay Kit is designed for the quantitative measurement of CRP and SAA levels in human blood samples. Utilizing immunofluorescence chromatography, this kit provides accurate and reliable results, making it an essential tool in clinical diagnostics for assessing inflammatory conditions.

1. The kit features a highly sensitive fluorescence pad that ensures precise detection of CRP and SAA levels. The use of monoclonal antibodies enhances specificity, reducing the likelihood of cross-reactivity with other proteins.
2. The test card's structure includes a nitrocellulose membrane that captures the target proteins, while the absorbent paper ensures efficient sample flow. The PVC backing provides stability and durability to the test card.
3. This kit is primarily used in clinical settings to monitor inflammatory responses. It is particularly useful in diagnosing and managing conditions such as infections, autoimmune diseases, and cardiovascular disorders.

The CRP/SAA Assay Kit is a sophisticated diagnostic tool that combines advanced immunofluorescence technology with a robust design. Its ability to accurately measure inflammation markers makes it indispensable in modern medicine. The kit's components are meticulously designed to ensure reliability and ease of use, making it a preferred choice for healthcare professionals.

Main Features

The CRP/SAA Assay Kit offers high sensitivity and specificity in detecting inflammation markers. Its user-friendly design and reliable performance make it a valuable tool in clinical diagnostics.

1. The kit employs immunofluorescence chromatography, which provides high sensitivity and specificity in detecting CRP and SAA levels.
2. The test card is designed for easy handling, with a clear layout that simplifies the testing process.
3. The sample buffer ensures optimal conditions for the reaction, enhancing the accuracy of the results.
4. The information card provides essential data, including the standard curve, which is crucial for interpreting the test results.
5. The kit is compatible with various sample types, including serum, plasma, and whole blood, making it versatile for different clinical settings.

The CRP/SAA Assay Kit stands out for its precision and ease of use. Its comprehensive design ensures that healthcare professionals can rely on it for accurate inflammation marker detection, aiding in the diagnosis and management of various conditions.

Clinical Applications

The CRP/SAA Assay Kit is widely used in clinical settings to assess inflammatory conditions. Its ability to provide quantitative results makes it a valuable tool for diagnosing and monitoring diseases.

1. The kit is used in hospitals and clinics to diagnose infections, as elevated CRP and SAA levels are indicative of an inflammatory response.
2. It is also employed in the management of autoimmune diseases, where monitoring inflammation is crucial for treatment efficacy.
3. In cardiovascular care, the kit helps in assessing the risk of heart disease by measuring inflammation markers.
4. The kit is used in research settings to study the role of inflammation in various diseases, providing valuable insights into disease mechanisms.
5. It is also utilized in emergency medicine to quickly assess the severity of inflammatory conditions, aiding in timely decision-making.

The CRP/SAA Assay Kit is a versatile tool in clinical practice, offering valuable insights into inflammatory conditions. Its applications span across various medical fields, making it an essential component of modern healthcare.

Purchasing Guide

When purchasing the CRP/SAA Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical needs.

1. Product specifications: Ensure the kit meets the required sensitivity and specificity for your diagnostic needs.
2. Product types: Choose between different formats, such as single-use or multi-use kits, based on your testing volume.
3. Budget: Consider the cost-effectiveness of the kit, including the price per test and the overall value it provides.
4. Usage scenarios: Evaluate the kit's compatibility with your laboratory equipment and the types of samples you will be testing.

Selecting the right CRP/SAA Assay Kit involves careful consideration of various factors. By focusing on product specifications, types, budget, and usage scenarios, you can ensure that the kit aligns with your clinical requirements and provides reliable results.

 Precautions

Proper handling and storage of the CRP/SAA Assay Kit are essential to ensure accurate results and prolong its shelf life.

1. Store the kit at the recommended temperature to maintain the stability of the reagents.
2. Handle the test cards with care to avoid contamination, which could affect the accuracy of the results.
3. Follow the manufacturer's instructions for sample preparation and testing procedures to ensure reliable outcomes.
4. Dispose of used materials according to biohazard waste disposal guidelines to maintain a safe laboratory environment.
5. Regularly calibrate and maintain the equipment used with the kit to ensure consistent performance.

Adhering to the recommended precautions is crucial for the effective use of the CRP/SAA Assay Kit. Proper storage, handling, and disposal practices not only ensure accurate results but also contribute to a safe and efficient laboratory environment.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files