Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
C-Reactive Protein Assay Kit (Latex-Enhanced Immunoturbidimetric Method)
The kit consists of two main reagents: Reagent 1 and Reagent 2. Reagent 1 contains Tris buffer (100mmol/L, pH 7.0) and PEG6000 (5g/L). Reagent 2 includes latex particles coated with goat anti-human CRP antibodies (20% W/W) and Tris buffer (100mmol/L, pH 7.0). These components work together to ensure accurate and reliable measurement of CRP levels in human serum or plasma samples.
Product English Name:
C-Reactive Protein Assay Kit (Latex-Enhanced Immunoturbidimetric Method)
Alias:
CRP Assay Kit,Latex-Enhanced CRP Kit
Intended Use:
This kit is designed to measure the concentration of C-reactive protein (CRP) in human serum or plasma. CRP is a key biomarker for non-specific inflammation, making this kit essential for diagnosing and monitoring inflammatory conditions in clinical settings.
Product Introduction

The C-Reactive Protein Assay Kit (Latex-Enhanced Immunoturbidimetric Method) is a highly sensitive and specific tool for quantifying CRP levels in human serum or plasma. It employs a latex-enhanced immunoturbidimetric method, which enhances the detection sensitivity and accuracy. This kit is widely used in clinical laboratories for diagnosing and monitoring inflammatory diseases, infections, and other conditions where CRP levels are indicative of disease activity.

1. The kit features a latex-enhanced immunoturbidimetric method, which significantly improves the sensitivity and specificity of CRP detection. This method allows for the precise measurement of CRP levels even at low concentrations, making it ideal for early detection of inflammatory conditions.
2. The kit is composed of two main reagents: Reagent 1, which contains Tris buffer and PEG6000, and Reagent 2, which includes latex particles coated with goat anti-human CRP antibodies. These components are carefully formulated to ensure optimal performance and reliability in CRP measurement.
3. The primary use of this kit is to measure CRP levels in human serum or plasma. CRP is a well-known biomarker for inflammation, and its levels are often elevated in response to infections, tissue injury, and chronic inflammatory diseases. This kit is therefore an essential tool for clinicians in diagnosing and managing these conditions.

The C-Reactive Protein Assay Kit is a vital tool in the clinical laboratory, offering a reliable and sensitive method for measuring CRP levels. Its latex-enhanced immunoturbidimetric method ensures accurate results, making it indispensable for diagnosing and monitoring inflammatory conditions. Whether you're dealing with acute infections or chronic inflammatory diseases, this kit provides the precision and reliability needed for effective patient care.

Main Features

The C-Reactive Protein Assay Kit offers high sensitivity and specificity in measuring CRP levels, making it an essential tool for clinical diagnostics. Its latex-enhanced immunoturbidimetric method ensures accurate and reliable results, even at low CRP concentrations.

1. High Sensitivity: The latex-enhanced immunoturbidimetric method allows for the detection of CRP at very low concentrations, making it ideal for early diagnosis of inflammatory conditions.
2. Specificity: The use of goat anti-human CRP antibodies ensures that the kit specifically targets CRP, reducing the risk of cross-reactivity with other proteins.
3. Reliability: The kit's components are carefully formulated to ensure consistent performance, providing reliable results in every test.
4. Ease of Use: The kit is designed for straightforward use in clinical laboratories, with clear instructions and minimal preparation required.
5. Wide Application: The kit is suitable for a variety of clinical settings, including hospitals, research laboratories, and diagnostic centers, making it a versatile tool for CRP measurement.

The C-Reactive Protein Assay Kit stands out for its high sensitivity, specificity, and reliability. Its latex-enhanced immunoturbidimetric method ensures accurate CRP measurement, making it a trusted tool in clinical diagnostics. Whether you're diagnosing acute infections or monitoring chronic inflammatory diseases, this kit delivers the precision and consistency needed for effective patient care.

Clinical Applications

The C-Reactive Protein Assay Kit is widely used in clinical settings to diagnose and monitor inflammatory conditions. Its ability to accurately measure CRP levels makes it an essential tool for clinicians.

1. Diagnosis of Infections: Elevated CRP levels are often indicative of bacterial infections, making this kit a valuable tool for diagnosing and monitoring such conditions.
2. Monitoring Chronic Inflammatory Diseases: The kit is used to monitor CRP levels in patients with chronic inflammatory diseases such as rheumatoid arthritis, helping clinicians assess disease activity and treatment efficacy.
3. Post-Surgical Monitoring: CRP levels can rise after surgery due to tissue injury and inflammation. This kit is used to monitor CRP levels post-surgery to detect potential complications.
4. Cardiovascular Risk Assessment: Elevated CRP levels are associated with an increased risk of cardiovascular events. This kit is used to assess CRP levels as part of cardiovascular risk assessment.
5. Research Applications: The kit is also used in research settings to study the role of CRP in various diseases and conditions, providing valuable insights into disease mechanisms and potential therapeutic targets.

The C-Reactive Protein Assay Kit is a versatile tool in clinical practice, used for diagnosing infections, monitoring chronic inflammatory diseases, assessing cardiovascular risk, and more. Its ability to provide accurate and reliable CRP measurements makes it an indispensable resource for clinicians and researchers alike.

Purchasing Guide

When purchasing the C-Reactive Protein Assay Kit, it's important to consider product specifications, types, budget, and intended use to ensure you select the right kit for your needs.

1. Product Specifications: Ensure the kit meets your laboratory's requirements for sensitivity, specificity, and reliability. Check the kit's components, such as the concentration of reagents and the type of antibodies used.
2. Product Types: There are different types of CRP assay kits available, including those with different detection methods. Choose a kit that aligns with your laboratory's capabilities and the specific needs of your clinical or research applications.
3. Budget: Consider the cost of the kit, including any additional reagents or equipment that may be required. Ensure the kit fits within your laboratory's budget while still meeting your quality standards.
4. Intended Use: Determine the primary use of the kit, whether for routine clinical diagnostics, research, or specialized applications. This will help you select a kit that is best suited for your specific needs.

Selecting the right C-Reactive Protein Assay Kit involves careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that you choose a kit that meets your laboratory's needs and provides reliable and accurate CRP measurements.

 Precautions

Proper handling and storage of the C-Reactive Protein Assay Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Storage Conditions: Store the kit at the recommended temperature to maintain the stability of the reagents. Avoid exposure to extreme temperatures or direct sunlight.
2. Handling: Use aseptic techniques when handling the reagents to prevent contamination. Ensure all equipment and surfaces are clean and free from contaminants.
3. Expiration Date: Always check the expiration date of the kit before use. Do not use expired reagents as they may yield inaccurate results.
4. Reagent Preparation: Follow the manufacturer's instructions for preparing and mixing the reagents. Incorrect preparation can affect the performance of the kit.
5. Disposal: Dispose of used reagents and materials according to local regulations and laboratory protocols to ensure safety and environmental compliance.

Proper storage, handling, and disposal of the C-Reactive Protein Assay Kit are crucial for maintaining the accuracy and reliability of your results. By following these precautions, you can ensure that the kit performs as expected and provides consistent, high-quality CRP measurements.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files