The C-Reactive Protein (CRP) Detection Kit (Latex Immunoturbidimetric Method) is a high-quality diagnostic tool used to measure CRP levels in human serum or plasma. CRP is a protein produced by the liver in response to inflammation, and its levels can indicate the presence of infections, autoimmune diseases, or cardiovascular risks. This kit utilizes latex particles coated with anti-human CRP antibodies to provide accurate and reliable results, making it a valuable tool for clinical laboratories and healthcare professionals.
1. The CRP Detection Kit is characterized by its high sensitivity and specificity, ensuring precise measurement of CRP levels even at low concentrations. The latex immunoturbidimetric method used in this kit offers a rapid and efficient way to detect CRP, making it suitable for high-throughput testing in clinical settings.
2. The kit is composed of two main reagents: Reagent 1, which contains a glycine buffer, PEG, NaCl, and proclin-300, and Reagent 2, which includes a glycine buffer, latex particles coated with anti-human CRP antibodies, proclin-300, and Tween-20. These components are carefully formulated to ensure stability and accuracy in CRP detection.
3. The primary use of this kit is for the quantitative detection of CRP in human serum or plasma. It is widely used in clinical diagnostics to monitor inflammatory conditions, assess cardiovascular risk, and detect infections or autoimmune diseases. The kit is also used in research settings to study the role of CRP in various diseases.
The CRP Detection Kit is a reliable and efficient tool for measuring CRP levels in human serum or plasma. Its high sensitivity and specificity make it a valuable asset in clinical diagnostics, particularly for monitoring inflammation and assessing cardiovascular risk. The kit's carefully formulated reagents ensure accurate and consistent results, making it a trusted choice for healthcare professionals.
The CRP Detection Kit offers high sensitivity, specificity, and rapid results, making it ideal for clinical diagnostics and research. Its latex immunoturbidimetric method ensures accurate CRP measurement.
1. High Sensitivity: The kit can detect CRP levels at very low concentrations, making it suitable for early detection of inflammation or infection.
2. Specificity: The use of latex particles coated with anti-human CRP antibodies ensures that the kit specifically targets CRP, reducing the risk of cross-reactivity with other proteins.
3. Rapid Results: The latex immunoturbidimetric method provides quick and reliable results, making it ideal for high-throughput testing in clinical laboratories.
4. Stability: The reagents are formulated to maintain stability over time, ensuring consistent performance and accurate results.
5. Versatility: The kit can be used with both serum and plasma samples, making it a versatile tool for various clinical and research applications.
The CRP Detection Kit stands out for its high sensitivity, specificity, and rapid results. Its ability to detect low CRP levels and provide quick, reliable results makes it an essential tool for clinical diagnostics. The kit's stability and versatility further enhance its value, making it a trusted choice for healthcare professionals.
The CRP Detection Kit is widely used in clinical settings to monitor inflammation, assess cardiovascular risk, and detect infections or autoimmune diseases. It is also used in research to study CRP's role in various conditions.
1. Inflammation Monitoring: The kit is commonly used to monitor CRP levels in patients with chronic inflammatory conditions, such as rheumatoid arthritis or lupus, to assess disease activity and treatment efficacy.
2. Cardiovascular Risk Assessment: Elevated CRP levels are associated with an increased risk of cardiovascular diseases. The kit is used to measure CRP levels in patients to assess their cardiovascular risk and guide treatment decisions.
3. Infection Detection: CRP levels rise in response to infections. The kit is used to detect and monitor infections, particularly in patients with suspected sepsis or other serious infections.
4. Autoimmune Disease Diagnosis: The kit is used to measure CRP levels in patients with suspected autoimmune diseases, such as lupus or vasculitis, to aid in diagnosis and monitor disease progression.
5. Research Applications: The kit is also used in research settings to study the role of CRP in various diseases, including cancer, diabetes, and neurodegenerative disorders.
The CRP Detection Kit is a versatile tool with a wide range of clinical applications. Its ability to monitor inflammation, assess cardiovascular risk, and detect infections makes it an invaluable asset in healthcare. Additionally, its use in research further highlights its importance in understanding the role of CRP in various diseases.
When purchasing the CRP Detection Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your clinical or research needs.
1. Product Specifications: Ensure the kit meets your laboratory's requirements for sensitivity, specificity, and detection range. Check the kit's compatibility with your existing equipment and protocols.
2. Product Types: Different kits may offer varying levels of sensitivity or be designed for specific applications (e.g., high-throughput testing or research). Choose a kit that aligns with your intended use.
3. Budget: Consider the cost of the kit, including any additional reagents or equipment that may be required. Balance cost with the kit's performance and reliability.
4. Intended Use: Determine whether the kit will be used for clinical diagnostics, research, or both. Ensure the kit's features align with your specific needs, such as the ability to process serum or plasma samples.
Purchasing the CRP Detection Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select a kit that meets your clinical or research needs and ensures accurate, reliable results.
Proper handling, storage, and usage of the CRP Detection Kit are essential to ensure accurate results and maintain the integrity of the reagents.
1. Storage Conditions: Store the kit at the recommended temperature (usually 2-8°C) to maintain reagent stability. Avoid freezing or exposing the kit to extreme temperatures.
2. Handling: Use aseptic techniques when handling reagents to prevent contamination. Wear appropriate personal protective equipment (PPE) when working with biological samples.
3. Reagent Preparation: Follow the manufacturer's instructions for preparing and mixing reagents. Ensure that all components are thoroughly mixed before use.
4. Sample Handling: Use fresh serum or plasma samples for testing. Avoid using hemolyzed, lipemic, or icteric samples, as they may interfere with the assay.
5. Calibration and Quality Control: Regularly calibrate the assay and run quality control samples to ensure the accuracy and reliability of the results.
To ensure the accuracy and reliability of the CRP Detection Kit, it is crucial to follow proper storage, handling, and usage guidelines. By adhering to these precautions, you can maintain the integrity of the reagents and obtain consistent, reliable results in your clinical or research applications.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.