Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
C-Reactive Protein Test Kit (Latex Immunoturbidimetric Method)
The kit consists of Reagent I (R1), Reagent II (R2), calibrators, and controls. R1 contains Tris buffer (20 mol/L, pH 7.2) and sodium azide (0.95 g/L). R2 includes latex particles coated with goat anti-human CRP (≥8 ml/L) and sodium azide (0.95 g/L). The calibrator is an aqueous solution containing CRP, while the control is a lyophilized product containing anti-streptolysin O, rheumatoid factor, and CRP. The CRP calibrator concentration is (160.0 ± 11.06) mg/L, and the CRP control concentration is (55 ± 4.38) mg/L.
Product English Name:
C-Reactive Protein Test Kit (Latex Immunoturbidimetric Method)
Alias:
CRP Test Kit,Latex CRP Assay
Intended Use:
This kit is designed for the quantitative determination of C-reactive protein (CRP) concentration in human serum in vitro. It is widely used in clinical laboratories to assess inflammation and monitor disease progression.
Product Introduction

The C-Reactive Protein Test Kit (Latex Immunoturbidimetric Method) is a highly sensitive and specific diagnostic tool used to measure CRP levels in human serum. CRP is a key biomarker for inflammation and infection, making this kit essential for diagnosing and monitoring various medical conditions. The kit employs a latex immunoturbidimetric method, ensuring accurate and reliable results. It is widely used in clinical settings due to its ease of use, precision, and compatibility with automated analyzers.

1. The kit features a latex immunoturbidimetric method, which enhances sensitivity and specificity in detecting CRP levels. This method ensures minimal interference from other serum components, providing reliable results.
2. The kit's composition includes Reagent I (R1) and Reagent II (R2), along with calibrators and controls. R1 contains Tris buffer and sodium azide, while R2 consists of latex particles coated with goat anti-human CRP. The calibrators and controls are designed to ensure accuracy and consistency in measurements.
3. The primary use of this kit is to quantitatively determine CRP levels in human serum. It is particularly useful in diagnosing inflammatory conditions, monitoring disease progression, and assessing the effectiveness of treatments.

The C-Reactive Protein Test Kit, also known as the CRP Test Kit or Latex CRP Assay, is a vital tool in clinical diagnostics. Its latex immunoturbidimetric method ensures high sensitivity and specificity, making it a reliable choice for measuring CRP levels. The kit's well-designed composition and ease of use make it a staple in laboratories worldwide.

Main Features

The C-Reactive Protein Test Kit offers high sensitivity, specificity, and reliability in measuring CRP levels. It is compatible with automated analyzers and provides consistent results, making it ideal for clinical use.

1. High Sensitivity: The kit's latex immunoturbidimetric method ensures accurate detection of low CRP levels, making it suitable for early diagnosis of inflammatory conditions.
2. Specificity: The use of goat anti-human CRP-coated latex particles minimizes cross-reactivity, ensuring precise measurements.
3. Compatibility: The kit is designed to work seamlessly with automated analyzers, reducing manual intervention and improving workflow efficiency.
4. Consistency: The inclusion of calibrators and controls ensures consistent and reproducible results across different batches and laboratories.
5. Ease of Use: The kit's straightforward protocol and clear instructions make it accessible to both experienced and novice laboratory personnel.

The C-Reactive Protein Test Kit stands out for its high sensitivity, specificity, and compatibility with automated systems. Its consistent performance and ease of use make it an indispensable tool in clinical diagnostics, helping healthcare professionals accurately measure CRP levels and monitor patient health.

Clinical Applications

The C-Reactive Protein Test Kit is widely used in clinical settings to diagnose and monitor inflammatory conditions, infections, and autoimmune diseases. It is also used to assess the risk of cardiovascular diseases.

1. Inflammatory Conditions: The kit is used to diagnose and monitor conditions such as rheumatoid arthritis, lupus, and other autoimmune diseases by measuring CRP levels.
2. Infections: Elevated CRP levels indicate bacterial or viral infections, making the kit useful for diagnosing and monitoring infectious diseases.
3. Cardiovascular Risk Assessment: CRP is a marker for inflammation in blood vessels, and its levels are used to assess the risk of heart disease and stroke.
4. Post-Surgical Monitoring: The kit is used to monitor CRP levels after surgery to detect complications such as infections or inflammation.
5. Chronic Disease Management: The kit helps in managing chronic conditions like diabetes and obesity by monitoring inflammation levels.

The C-Reactive Protein Test Kit is a versatile tool in clinical practice, aiding in the diagnosis and monitoring of various inflammatory and infectious conditions. Its ability to assess cardiovascular risk and monitor post-surgical recovery makes it an essential component of modern healthcare.

Purchasing Guide

When purchasing the C-Reactive Protein Test Kit, consider factors such as product specifications, types, budget, and intended use to ensure it meets your laboratory's needs.

1. Product Specifications: Evaluate the kit's sensitivity, specificity, and compatibility with your laboratory's analyzers to ensure accurate and reliable results.
2. Product Types: Choose between different kit formats (e.g., manual vs. automated) based on your laboratory's workflow and volume of tests.
3. Budget: Consider the cost per test and overall budget to ensure the kit is cost-effective for your laboratory.
4. Intended Use: Ensure the kit is suitable for your specific applications, such as diagnosing inflammatory conditions, monitoring infections, or assessing cardiovascular risk.

Purchasing the C-Reactive Protein Test Kit requires careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can select a kit that meets your laboratory's needs and ensures accurate and reliable CRP measurements.

 Precautions

Proper handling, storage, and usage of the C-Reactive Protein Test Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Storage: Store the kit at the recommended temperature (2-8°C) to maintain reagent stability and prevent degradation.
2. Handling: Use aseptic techniques when handling reagents to avoid contamination, which can affect test results.
3. Calibration: Regularly calibrate the kit using the provided calibrators to ensure accurate and consistent measurements.
4. Expiry Date: Always check the expiry date before use and do not use expired reagents, as they may yield unreliable results.
5. Disposal: Dispose of used reagents and materials according to local regulations to ensure safety and environmental compliance.

To ensure the accuracy and reliability of the C-Reactive Protein Test Kit, it is crucial to follow proper storage, handling, and usage guidelines. Regular calibration and adherence to expiry dates and disposal regulations further enhance the kit's performance and safety in the laboratory.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files