Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
C-Reactive Protein (CRP) Detection Kit (Latex Turbidimetric Method)
The CRP Detection Kit consists of two main reagents: Reagent A, a glycine buffer containing sodium azide, and Reagent B, CRP-sensitized latex particles also containing sodium azide. Additionally, it includes a standard S, which is a CRP standard in human serum. These components work together to provide accurate and reliable measurements of CRP levels in human serum.
Product English Name:
C-Reactive Protein (CRP) Detection Kit (Latex Turbidimetric Method)
Alias:
CRP Test Kit,Latex CRP Assay
Intended Use:
This product is specifically designed for the quantitative determination of C-reactive protein (CRP) concentration in human serum. CRP is a key biomarker for inflammation and infection, making this kit essential for clinical diagnostics and monitoring of inflammatory conditions.
Product Introduction

The C-Reactive Protein (CRP) Detection Kit (Latex Turbidimetric Method) is a high-quality diagnostic tool used to measure CRP levels in human serum. CRP is a protein produced by the liver in response to inflammation, and its levels can indicate the presence of infection, tissue damage, or chronic inflammatory diseases. This kit is widely used in clinical laboratories due to its accuracy, reliability, and ease of use.

1. The CRP Detection Kit is known for its high sensitivity and specificity, ensuring accurate detection of CRP levels even at low concentrations. The latex turbidimetric method used in this kit provides rapid results, making it ideal for clinical settings where quick diagnosis is crucial.
2. The kit is composed of two main reagents: Reagent A, a glycine buffer with sodium azide, and Reagent B, CRP-sensitized latex particles also containing sodium azide. These reagents are designed to react specifically with CRP in the serum, forming aggregates that can be measured turbidimetrically.
3. The primary use of this kit is to measure CRP levels in human serum, which is a critical marker for inflammation and infection. Elevated CRP levels can indicate a range of conditions, from acute infections to chronic inflammatory diseases, making this kit an essential tool for clinicians.

The CRP Detection Kit is a reliable and efficient tool for measuring CRP levels in human serum. Its high sensitivity and specificity make it a valuable asset in clinical diagnostics, particularly for identifying and monitoring inflammatory conditions. The kit's ease of use and rapid results further enhance its utility in busy clinical laboratories.

Main Features

The CRP Detection Kit offers high sensitivity, specificity, and rapid results, making it an essential tool for clinical diagnostics. Its latex turbidimetric method ensures accurate measurement of CRP levels in human serum.

1. High Sensitivity: The kit can detect CRP levels even at low concentrations, ensuring accurate diagnosis of inflammatory conditions.
2. Specificity: The CRP-sensitized latex particles react specifically with CRP in the serum, minimizing the risk of false positives.
3. Rapid Results: The latex turbidimetric method provides quick results, making it ideal for clinical settings where time is of the essence.
4. Ease of Use: The kit is designed for straightforward operation, requiring minimal training for laboratory personnel.
5. Reliability: The inclusion of a CRP standard ensures consistent and reliable results across different batches and laboratories.

The CRP Detection Kit stands out for its high sensitivity, specificity, and rapid results. Its ease of use and reliability make it a preferred choice for clinical laboratories, ensuring accurate and timely diagnosis of inflammatory conditions.

Clinical Applications

The CRP Detection Kit is widely used in clinical settings to diagnose and monitor inflammatory conditions, infections, and tissue damage. Its accurate measurement of CRP levels aids in the early detection and management of various diseases.

1. Diagnosis of Infections: Elevated CRP levels can indicate the presence of bacterial or viral infections, making this kit essential for early diagnosis.
2. Monitoring Chronic Inflammatory Diseases: The kit is used to monitor CRP levels in patients with chronic conditions such as rheumatoid arthritis and lupus.
3. Post-Surgical Monitoring: CRP levels are often monitored after surgery to detect any signs of infection or inflammation.
4. Cardiovascular Risk Assessment: Elevated CRP levels are associated with an increased risk of cardiovascular diseases, making this kit useful for risk assessment.
5. Research Applications: The kit is also used in research settings to study the role of CRP in various diseases and conditions.

The CRP Detection Kit is a versatile tool in clinical diagnostics, used for diagnosing infections, monitoring chronic inflammatory diseases, and assessing cardiovascular risk. Its applications extend to post-surgical monitoring and research, making it an invaluable asset in both clinical and research settings.

Purchasing Guide

When purchasing the CRP Detection Kit, consider factors such as product specifications, types, budget, and intended use to ensure you select the right product for your needs.

1. Product Specifications: Ensure the kit meets your laboratory's requirements for sensitivity, specificity, and accuracy.
2. Product Types: Choose between different kit formats, such as single-use or bulk packs, based on your laboratory's volume needs.
3. Budget: Consider the cost per test and overall budget when selecting a kit to ensure cost-effectiveness.
4. Intended Use: Select a kit that is suitable for your specific clinical or research applications, ensuring it meets all necessary regulatory standards.

Selecting the right CRP Detection Kit involves careful consideration of product specifications, types, budget, and intended use. By evaluating these factors, you can ensure that the kit you choose meets your laboratory's needs and provides reliable results.

 Precautions

Proper handling and storage of the CRP Detection Kit are essential to ensure accurate results and maintain the integrity of the reagents.

1. Storage Conditions: Store the kit at the recommended temperature to prevent degradation of the reagents.
2. Handling: Follow proper laboratory procedures when handling the reagents to avoid contamination.
3. Expiration Date: Always check the expiration date before use to ensure the reagents are still effective.
4. Disposal: Dispose of used reagents and materials according to local regulations to ensure safety and environmental compliance.
5. Training: Ensure all laboratory personnel are properly trained in the use of the kit to avoid errors and ensure accurate results.

Proper storage, handling, and disposal of the CRP Detection Kit are crucial for maintaining its effectiveness and ensuring accurate results. Training laboratory personnel and adhering to expiration dates and storage conditions are key to successful use of the kit.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files