CRP/SAA Dual Detection Kit (Time-Resolved Fluorescence Immunochromatography)
The kit consists of a test card, calibration card, sample diluent, and product manual. The test card includes a test strip and a plastic cassette. The test strip is composed of a sample pad, conjugate pad, NC membrane, absorbent pad, and PVC backing. The conjugate pad is coated with time-resolved fluorescent microspheres labeled with CRP monoclonal antibody, SAA monoclonal antibody, and chicken IgY antibody. The calibration card contains pre-written product information and calibration curves. The sample diluent is a Tris-HCl buffer solution.
Product English Name:
CRP/SAA Dual Detection Kit (Time-Resolved Fluorescence Immunochromatography)
Alias:
CRP/SAA Combo Test Kit,Dual Biomarker Assay Kit
Intended Use:
This kit is designed for the in vitro quantitative detection of C-reactive protein (CRP) and serum amyloid A (SAA) in human serum, plasma, or whole blood. It is widely used in clinical settings to assess inflammation and infection levels, aiding in the diagnosis and monitoring of various diseases.
Product Introduction

The CRP/SAA Dual Detection Kit utilizes time-resolved fluorescence immunochromatography to provide accurate and reliable quantitative results for CRP and SAA levels. This innovative technology ensures high sensitivity and specificity, making it a valuable tool in clinical diagnostics. The kit is user-friendly, with a straightforward procedure that delivers quick results, making it suitable for both laboratory and point-of-care settings.

1. The kit features a unique combination of CRP and SAA detection in a single test, offering a comprehensive assessment of inflammatory markers. The use of time-resolved fluorescence enhances the sensitivity and accuracy of the results.
2. The test strip is composed of multiple layers, including a sample pad, conjugate pad, NC membrane, absorbent pad, and PVC backing. Each layer plays a crucial role in the accurate detection of CRP and SAA levels.
3. The kit is primarily used for the quantitative detection of CRP and SAA in human serum, plasma, or whole blood. It is widely applied in clinical settings to monitor inflammation and infection, aiding in the diagnosis and management of various diseases.

The CRP/SAA Dual Detection Kit is a powerful tool for clinicians, offering a quick and accurate way to measure two critical biomarkers of inflammation. Its dual detection capability and advanced fluorescence technology make it a standout choice for modern diagnostic needs.

Main Features

The CRP/SAA Dual Detection Kit offers high sensitivity and specificity, enabling precise measurement of CRP and SAA levels. Its dual detection capability and user-friendly design make it ideal for clinical use.

1. The kit provides simultaneous detection of CRP and SAA, offering a comprehensive assessment of inflammatory markers in a single test.
2. The use of time-resolved fluorescence technology ensures high sensitivity and accuracy, reducing the likelihood of false positives or negatives.
3. The test strip's multi-layered structure ensures efficient sample flow and accurate biomarker detection, with each layer playing a specific role in the process.
4. The kit is designed for ease of use, with a straightforward procedure that delivers quick results, making it suitable for both laboratory and point-of-care settings.
5. The calibration card included in the kit ensures consistent and reliable results, with pre-written product information and calibration curves.

The CRP/SAA Dual Detection Kit stands out for its dual detection capability, advanced fluorescence technology, and user-friendly design. It is a reliable and efficient tool for clinicians, offering quick and accurate results for inflammation monitoring.

Clinical Applications

The CRP/SAA Dual Detection Kit is widely used in clinical settings to monitor inflammation and infection levels, aiding in the diagnosis and management of various diseases.

1. The kit is used in hospitals and clinics to assess inflammation levels in patients, aiding in the diagnosis of conditions such as infections, autoimmune diseases, and cardiovascular diseases.
2. It is also used in research settings to study the role of CRP and SAA in various diseases, providing valuable insights into disease mechanisms and potential treatments.
3. The kit is particularly useful in emergency settings, where quick and accurate assessment of inflammation levels is crucial for patient management.
4. It is also used in routine health check-ups to monitor inflammation levels in healthy individuals, helping to identify potential health issues early.
5. The kit's dual detection capability makes it a valuable tool in the management of chronic diseases, where monitoring inflammation levels is essential for effective treatment.

The CRP/SAA Dual Detection Kit is a versatile tool in clinical practice, offering quick and accurate assessment of inflammation levels. Its dual detection capability and advanced technology make it a valuable asset in the diagnosis and management of various diseases.

Purchasing Guide

When purchasing the CRP/SAA Dual Detection Kit, consider factors such as product specifications, types, budget, and intended use to ensure you select the right product for your needs.

1. Product specifications: Ensure the kit meets your requirements for sensitivity, specificity, and detection range. Check the product manual for detailed specifications.
2. Product types: The kit is available in different formats, including single-use and multi-use options. Choose the type that best suits your clinical or research needs.
3. Budget: Consider the cost of the kit, including any additional reagents or equipment required for its use. Ensure the kit fits within your budget without compromising on quality.
4. Intended use: Consider the specific clinical or research applications for which you will use the kit. Ensure the kit is suitable for your intended use, whether in a laboratory, clinic, or point-of-care setting.

Selecting the right CRP/SAA Dual Detection Kit requires careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure you choose a kit that meets your needs and delivers reliable results.

 Precautions

When using the CRP/SAA Dual Detection Kit, it is important to follow the instructions carefully to ensure accurate results and avoid potential hazards.

1. Always wear appropriate personal protective equipment, such as gloves and lab coats, when handling the kit components to avoid contamination and exposure to hazardous materials.
2. Ensure the test card and calibration card are stored properly to maintain their integrity and performance. Avoid exposure to extreme temperatures or humidity.
3. Follow the sample preparation and handling instructions carefully to ensure accurate results. Improper sample handling can lead to inaccurate readings.
4. Dispose of used kit components and biohazard waste according to local regulations to avoid environmental contamination and health risks.
5. Regularly calibrate the kit using the provided calibration card to ensure consistent and reliable results. Failure to calibrate can lead to inaccurate readings.

Using the CRP/SAA Dual Detection Kit safely and effectively requires careful attention to handling, storage, and disposal procedures. By following the precautions outlined, you can ensure accurate results and minimize potential risks.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files