CRP/SAA Dual Detection Kit (Fluorescence Immunochromatography)
The kit consists of a reagent card, sample diluent, data card, and instruction manual. The reagent card includes a test strip and a plastic shell. The test strip is supported by a plastic backing and sequentially attached with absorbent paper, NC membrane, glass fiber conjugate pad, and sample pad. It is independently packaged in a reagent bag with a plastic shell of appropriate size. The conjugate pad is fixed with rabbit IgG microsphere conjugates, CRP antibody microsphere conjugates, and SAA antibody microsphere conjugates. The NC membrane is coated with goat anti-rabbit IgG, CRP monoclonal antibody, and SAA monoclonal antibody. The sample diluent is composed of 0.01M PBS buffer (pH 7.4±0.2), 0.85% sodium chloride, 1% S9, 0.2% Tween 20, and 0.03% Proclin 300 preservative. The reagent card is used in conjunction with an instrument to store data related to the kit, such as the project name, reagent lot number, production date, and standard curve.
Product English Name:
CRP/SAA Dual Detection Kit (Fluorescence Immunochromatography)
Alias:
CRP/SAA Test Kit,Inflammation Marker Kit
Intended Use:
This kit is used for the in vitro quantitative determination of C-reactive protein (CRP) and serum amyloid A (SAA) in human serum, plasma, or whole blood samples. It serves as a non-specific inflammatory marker, aiding in the diagnosis and monitoring of inflammatory conditions.
Product Introduction

The CRP/SAA Dual Detection Kit (Fluorescence Immunochromatography) is a cutting-edge diagnostic tool designed for the simultaneous quantitative detection of C-reactive protein (CRP) and serum amyloid A (SAA) in human samples. This kit is essential for clinicians and researchers aiming to assess inflammatory responses accurately. Its advanced fluorescence immunochromatography technology ensures high sensitivity and specificity, making it a reliable choice for both clinical and research settings.

1. The kit features a unique design that integrates multiple components, including a reagent card, sample diluent, and data card, ensuring ease of use and accurate results. The reagent card is meticulously constructed with a test strip that includes a plastic backing, absorbent paper, NC membrane, and glass fiber conjugate pad, all housed within a plastic shell for protection.
2. The composition of the kit is carefully engineered to provide optimal performance. The conjugate pad is embedded with rabbit IgG microsphere conjugates, CRP antibody microsphere conjugates, and SAA antibody microsphere conjugates, while the NC membrane is coated with goat anti-rabbit IgG, CRP monoclonal antibody, and SAA monoclonal antibody. This intricate setup ensures precise detection of CRP and SAA levels.
3. The primary use of this kit is to quantitatively measure CRP and SAA in human serum, plasma, or whole blood samples. It is particularly valuable as a non-specific inflammatory marker, aiding in the diagnosis and monitoring of various inflammatory conditions. The kit's ability to provide rapid and accurate results makes it an indispensable tool in clinical diagnostics.

The CRP/SAA Dual Detection Kit is a sophisticated diagnostic tool that combines advanced technology with a user-friendly design. Its ability to simultaneously detect CRP and SAA levels with high precision makes it a valuable asset in both clinical and research environments. The kit's comprehensive composition and ease of use ensure reliable results, making it a trusted choice for healthcare professionals.

Main Features

The CRP/SAA Dual Detection Kit offers high sensitivity and specificity in detecting CRP and SAA levels, making it a reliable tool for assessing inflammatory responses. Its user-friendly design and advanced technology ensure accurate and rapid results.

1. The kit utilizes fluorescence immunochromatography technology, which enhances the sensitivity and specificity of CRP and SAA detection. This technology allows for the precise measurement of these biomarkers, even at low concentrations.
2. The reagent card is designed for ease of use, with a test strip that includes a plastic backing, absorbent paper, NC membrane, and glass fiber conjugate pad. This design ensures that the sample is evenly distributed across the test strip, leading to accurate and consistent results.
3. The conjugate pad is embedded with rabbit IgG microsphere conjugates, CRP antibody microsphere conjugates, and SAA antibody microsphere conjugates. These conjugates are specifically designed to bind to CRP and SAA, ensuring that the detection is highly specific and accurate.
4. The NC membrane is coated with goat anti-rabbit IgG, CRP monoclonal antibody, and SAA monoclonal antibody. This coating ensures that the captured CRP and SAA are firmly bound to the membrane, allowing for precise detection and measurement.
5. The sample diluent is carefully formulated to ensure optimal performance. It includes 0.01M PBS buffer, 0.85% sodium chloride, 1% S9, 0.2% Tween 20, and 0.03% Proclin 300 preservative. This formulation ensures that the sample is properly diluted and preserved, leading to accurate and reliable results.

The CRP/SAA Dual Detection Kit is a powerful tool for assessing inflammatory responses. Its advanced technology and user-friendly design make it a reliable choice for clinicians and researchers. The kit's ability to provide rapid and accurate results ensures that it is a valuable asset in both clinical and research settings.

Clinical Applications

The CRP/SAA Dual Detection Kit is widely used in clinical settings for the diagnosis and monitoring of inflammatory conditions. Its ability to provide rapid and accurate results makes it an essential tool for healthcare professionals.

1. The kit is commonly used in hospitals and clinics for the diagnosis of inflammatory conditions such as infections, autoimmune diseases, and chronic inflammatory disorders. Its ability to provide rapid results allows for timely diagnosis and treatment.
2. In research settings, the kit is used to study the role of CRP and SAA in various inflammatory conditions. Researchers can use the kit to measure CRP and SAA levels in different samples, providing valuable insights into the mechanisms of inflammation.
3. The kit is also used in emergency settings, where rapid diagnosis of inflammatory conditions is crucial. Its ability to provide accurate results in a short amount of time makes it an invaluable tool for emergency healthcare providers.
4. In addition to its use in human medicine, the kit is also used in veterinary medicine to diagnose inflammatory conditions in animals. Its versatility and reliability make it a valuable tool for veterinarians.
5. The kit is also used in public health settings to monitor the spread of infectious diseases. By measuring CRP and SAA levels in populations, public health officials can identify outbreaks and implement control measures.

The CRP/SAA Dual Detection Kit is a versatile tool that is widely used in clinical, research, and public health settings. Its ability to provide rapid and accurate results makes it an essential tool for healthcare professionals and researchers. The kit's versatility and reliability ensure that it is a valuable asset in the fight against inflammatory conditions.

Purchasing Guide

When purchasing the CRP/SAA Dual Detection Kit, it is important to consider factors such as product specifications, types, budget, and usage scenarios to ensure that the kit meets your specific needs.

1. Product specifications: Ensure that the kit meets the required specifications for your intended use. Check the sensitivity, specificity, and detection range of the kit to ensure that it is suitable for your needs.
2. Product types: There are different types of CRP/SAA detection kits available, each with its own unique features. Choose the type that best suits your needs, whether it is for clinical use, research, or public health monitoring.
3. Budget: Consider your budget when purchasing the kit. While it is important to choose a high-quality kit, it is also important to ensure that it fits within your budget. Compare prices from different suppliers to find the best deal.
4. Usage scenarios: Consider the specific scenarios in which you will be using the kit. If you need the kit for emergency use, for example, you may want to choose a kit that provides rapid results. If you need the kit for research, you may want to choose a kit with a wider detection range.

Purchasing the CRP/SAA Dual Detection Kit requires careful consideration of factors such as product specifications, types, budget, and usage scenarios. By taking these factors into account, you can ensure that you choose the kit that best meets your needs. The kit's versatility and reliability make it a valuable asset in a variety of settings.

 Precautions

When using the CRP/SAA Dual Detection Kit, it is important to follow the instructions carefully and take necessary precautions to ensure accurate results and safe handling of the kit components.

1. Always wear appropriate personal protective equipment (PPE) such as gloves and lab coats when handling the kit components. This will help prevent contamination and ensure safe handling of the samples.
2. Follow the instructions provided in the manual carefully. Improper use of the kit can lead to inaccurate results. Ensure that all components are used as directed and that the sample is properly prepared before testing.
3. Store the kit components at the recommended temperature. Improper storage can affect the performance of the kit and lead to inaccurate results. Ensure that the kit is stored in a cool, dry place away from direct sunlight.
4. Dispose of the kit components properly after use. Follow the local regulations for the disposal of biohazardous materials. Ensure that all used components are disposed of in a safe and environmentally friendly manner.
5. Regularly calibrate the equipment used with the kit to ensure accurate results. Calibration is essential for maintaining the performance of the kit and ensuring that the results are reliable.

Using the CRP/SAA Dual Detection Kit requires careful attention to safety and proper handling. By following the instructions and taking necessary precautions, you can ensure accurate results and safe handling of the kit components. The kit's reliability and ease of use make it a valuable tool for healthcare professionals and researchers.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files