Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
CRP/SAA Combined Test Kit (Fluorescence Immunochromatography)
The kit includes reagent cards, desiccant (1 pack/bag), buffer solution (1 bag/box), and a CODE card (1 card/box). The reagent card consists of a nitrocellulose membrane, glass fiber, absorbent paper, and a plastic carrier plate. The glass fiber contains mouse anti-CRP monoclonal labeled antibodies (0.02-1.0 mg/mL) and mouse anti-SAA monoclonal labeled antibodies (0.02-1.0 mg/mL). The nitrocellulose membrane contains mouse anti-CRP monoclonal coated antibodies (0.2-3.0 mg/mL) (T1 line), mouse anti-SAA monoclonal coated antibodies (0.2-3.0 mg/mL) (T2 line), and goat anti-mouse IgG antibodies (0.3-4.0 mg/mL) (C line). The CODE card is traceable to the CRP National Standard (No. 360039) and the SAA International Standard (NIBSC: 92/680).
Product English Name:
CRP/SAA Combined Test Kit (Fluorescence Immunochromatography)
Alias:
CRP/SAA Kit,Fluorescence Immunoassay Kit
Intended Use:
This product is used for the quantitative detection of C-reactive protein (CRP) and serum amyloid A (SAA) in human serum, plasma, or whole blood in vitro.
Product Introduction

The CRP/SAA Combined Test Kit is a state-of-the-art diagnostic tool designed for the simultaneous detection of C-reactive protein (CRP) and serum amyloid A (SAA) in human samples. Utilizing fluorescence immunochromatography, this kit offers high sensitivity and specificity, making it an essential tool for clinical diagnostics and research. The kit is composed of several key components, including reagent cards, a buffer solution, and a CODE card, all of which are designed to ensure accurate and reliable results.

1. The CRP/SAA Combined Test Kit is characterized by its high sensitivity and specificity, which are achieved through the use of advanced fluorescence immunochromatography technology. This technology allows for the precise detection of CRP and SAA levels in human serum, plasma, or whole blood, providing clinicians with critical information for diagnosing and monitoring various inflammatory conditions.
2. The kit's composition includes a reagent card made up of a nitrocellulose membrane, glass fiber, absorbent paper, and a plastic carrier plate. The glass fiber is embedded with mouse anti-CRP and anti-SAA monoclonal labeled antibodies, while the nitrocellulose membrane contains corresponding coated antibodies and a control line. This intricate structure ensures the accurate capture and detection of CRP and SAA.
3. The primary use of the CRP/SAA Combined Test Kit is for the quantitative detection of CRP and SAA in human samples. These biomarkers are crucial for diagnosing and monitoring inflammatory diseases, infections, and other conditions. The kit's ability to provide rapid and reliable results makes it an invaluable tool in clinical settings.

The CRP/SAA Combined Test Kit, also known as the Fluorescence Immunoassay Kit, is a highly specialized diagnostic tool designed for the simultaneous detection of CRP and SAA. Its advanced technology and precise composition make it an essential resource for clinicians and researchers alike, offering reliable and accurate results for the diagnosis and monitoring of various inflammatory conditions.

Main Features

The CRP/SAA Combined Test Kit offers high sensitivity and specificity for the detection of CRP and SAA, utilizing fluorescence immunochromatography technology to provide rapid and reliable results.

1. The kit's high sensitivity allows for the detection of low levels of CRP and SAA, making it suitable for early diagnosis and monitoring of inflammatory conditions.
2. The use of fluorescence immunochromatography ensures high specificity, reducing the likelihood of false positives and ensuring accurate results.
3. The kit is designed for ease of use, with a simple procedure that can be performed in a clinical setting without the need for specialized equipment.
4. The inclusion of a CODE card ensures traceability to national and international standards, providing confidence in the accuracy and reliability of the results.
5. The kit's components are carefully designed to ensure stability and longevity, with a desiccant included to maintain the integrity of the reagents.

The CRP/SAA Combined Test Kit stands out for its high sensitivity, specificity, and ease of use. Its advanced technology and reliable components make it a trusted tool for clinicians, offering rapid and accurate results for the diagnosis and monitoring of inflammatory conditions.

Clinical Applications

The CRP/SAA Combined Test Kit is widely used in clinical settings for the diagnosis and monitoring of inflammatory diseases, infections, and other conditions that involve elevated levels of CRP and SAA.

1. The kit is commonly used in hospitals and clinics for the rapid diagnosis of infections, allowing for timely treatment and management of patients.
2. It is also used in research settings to study the role of CRP and SAA in various diseases, providing valuable insights into the mechanisms of inflammation and immune response.
3. The kit's ability to provide quantitative results makes it useful for monitoring the progression of chronic inflammatory diseases, such as rheumatoid arthritis and lupus.
4. In emergency settings, the kit can be used to quickly assess the severity of infections or inflammatory conditions, aiding in the decision-making process for treatment.
5. The kit is also used in public health settings for the screening of populations at risk for inflammatory diseases, helping to identify individuals who may require further diagnostic testing or treatment.

The CRP/SAA Combined Test Kit is a versatile tool with a wide range of clinical applications. Its ability to provide rapid and accurate results makes it invaluable for the diagnosis and monitoring of inflammatory diseases, infections, and other conditions, benefiting both patients and healthcare providers.

Purchasing Guide

When purchasing the CRP/SAA Combined Test Kit, it is important to consider factors such as product specifications, types, budget, and intended use to ensure that the kit meets your specific needs.

1. Product specifications: Ensure that the kit includes all necessary components, such as reagent cards, buffer solution, and a CODE card, and that these components meet the required standards for sensitivity and specificity.
2. Product types: Consider the different types of kits available, such as those designed for specific sample types (serum, plasma, or whole blood) or those with different detection limits, to choose the one that best suits your needs.
3. Budget: Evaluate the cost of the kit in relation to its features and performance, ensuring that it provides good value for money while meeting your diagnostic requirements.
4. Intended use: Consider the specific clinical or research applications for which the kit will be used, and ensure that it is suitable for those purposes, including any regulatory requirements or guidelines that may apply.

Purchasing the CRP/SAA Combined Test Kit requires careful consideration of various factors, including product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that the kit you choose meets your specific needs and provides reliable and accurate results for your diagnostic or research purposes.

 Precautions

When using the CRP/SAA Combined Test Kit, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the integrity of the components.

1. Always handle the kit components with care, avoiding contamination and ensuring that they are stored at the recommended temperature to maintain their stability and effectiveness.
2. Follow the instructions provided in the kit's manual carefully, including the correct order of steps and the appropriate amount of sample to use, to ensure accurate and reliable results.
3. Dispose of used components properly, following local regulations for biohazardous waste, to prevent contamination and ensure safety.
4. Regularly check the expiration date of the kit and its components, and do not use expired materials, as this can affect the accuracy and reliability of the results.
5. If any issues or discrepancies are observed during the use of the kit, consult the manufacturer's technical support or refer to the troubleshooting section of the manual for guidance.

Proper handling and storage of the CRP/SAA Combined Test Kit are essential for ensuring accurate and reliable results. By following the recommended precautions and procedures, you can maintain the integrity of the kit's components and achieve the best possible outcomes in your diagnostic or research applications.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files