The C-Reactive Protein Assay Kit (Latex-Enhanced Immunoturbidimetric Method) is a highly sensitive and specific diagnostic tool used to measure CRP levels in human serum. CRP is a protein produced by the liver in response to inflammation, and its levels can rise significantly in conditions such as infections, autoimmune diseases, and cardiovascular disorders. This kit utilizes latex particles coated with anti-CRP antibodies to enhance the detection sensitivity, providing accurate and reproducible results.
1. The kit features a latex-enhanced immunoturbidimetric method, which significantly improves the sensitivity and specificity of CRP detection. This method allows for the precise measurement of CRP levels even at low concentrations, making it ideal for early detection of inflammatory conditions.
2. The composition of the kit includes two reagents: R1, which contains a phosphate buffer and PEG6000 to stabilize the reaction environment, and R2, which includes latex particles coated with anti-CRP antibodies and a stabilizer to ensure long-term reagent stability.
3. The primary use of this kit is for the quantitative determination of CRP in human serum, which is crucial for diagnosing and monitoring inflammatory diseases, infections, and cardiovascular risks. The kit is widely used in clinical laboratories and research settings due to its reliability and ease of use.
The C-Reactive Protein Assay Kit, also known as the CRP Assay Kit, is a vital tool in clinical diagnostics. Its latex-enhanced immunoturbidimetric method ensures high sensitivity and specificity, making it indispensable for measuring CRP levels in human serum. Whether you're diagnosing an infection or monitoring a chronic inflammatory condition, this kit provides the accuracy and reliability you need.
The C-Reactive Protein Assay Kit offers high sensitivity and specificity in detecting CRP levels, making it a reliable tool for clinical diagnostics. Its latex-enhanced immunoturbidimetric method ensures accurate and reproducible results.
1. High Sensitivity: The latex-enhanced method allows for the detection of CRP at very low concentrations, making it ideal for early diagnosis of inflammatory conditions.
2. Specificity: The use of anti-CRP antibodies ensures that the kit specifically targets CRP, reducing the risk of cross-reactivity with other proteins.
3. Stability: The inclusion of stabilizers in both R1 and R2 ensures that the reagents remain stable over time, providing consistent results.
4. Ease of Use: The kit is designed for straightforward operation, making it accessible for both clinical laboratories and research settings.
5. Reproducibility: The kit's design ensures that results are reproducible, which is crucial for reliable clinical diagnostics.
The C-Reactive Protein Assay Kit stands out for its high sensitivity, specificity, and ease of use. Whether you're in a clinical lab or a research setting, this kit provides the reliability and accuracy needed for effective CRP measurement. Its stability and reproducibility make it a trusted choice for diagnosing and monitoring inflammatory conditions.
The C-Reactive Protein Assay Kit is widely used in clinical settings for the diagnosis and monitoring of inflammatory conditions, infections, and cardiovascular diseases. Its accurate measurement of CRP levels is crucial for patient management.
1. Diagnosis of Infections: Elevated CRP levels are a key indicator of bacterial infections, making this kit essential for early diagnosis and treatment.
2. Monitoring Inflammatory Diseases: The kit is used to monitor conditions such as rheumatoid arthritis and lupus, where CRP levels can indicate disease activity.
3. Cardiovascular Risk Assessment: CRP is a marker for cardiovascular risk, and this kit is used to assess patients at risk of heart disease.
4. Post-Surgical Monitoring: CRP levels can rise after surgery, and this kit is used to monitor patients for potential complications.
5. Research Applications: The kit is also used in research settings to study the role of CRP in various diseases and conditions.
The C-Reactive Protein Assay Kit is a versatile tool in clinical diagnostics, used for everything from diagnosing infections to monitoring chronic inflammatory diseases. Its ability to accurately measure CRP levels makes it indispensable for patient care and research. Whether you're assessing cardiovascular risk or monitoring post-surgical recovery, this kit provides the data you need.
When purchasing the C-Reactive Protein Assay Kit, consider factors such as product specifications, types, budget, and intended use to ensure you select the right kit for your needs.
1. Product Specifications: Ensure the kit meets your laboratory's requirements for sensitivity, specificity, and stability.
2. Product Types: Choose between different kit formats, such as single-use or bulk packs, based on your laboratory's volume needs.
3. Budget: Consider the cost per test and the overall budget for your laboratory when selecting a kit.
4. Intended Use: Select a kit that is appropriate for your specific applications, whether for clinical diagnostics or research purposes.
Purchasing the right C-Reactive Protein Assay Kit involves careful consideration of your laboratory's needs and budget. By focusing on product specifications, types, and intended use, you can ensure that you select a kit that provides reliable and accurate results for your specific applications.
Proper handling and storage of the C-Reactive Protein Assay Kit are essential to ensure accurate results and maintain reagent stability. Follow all instructions carefully to avoid contamination and ensure reliable performance.
1. Storage Conditions: Store the kit at the recommended temperature to maintain reagent stability and prevent degradation.
2. Handling: Use aseptic techniques when handling reagents to avoid contamination, which can affect test results.
3. Expiration Date: Always check the expiration date before use, as expired reagents may not provide accurate results.
4. Calibration: Regularly calibrate your equipment to ensure that the kit performs as expected.
5. Disposal: Follow proper disposal procedures for used reagents and materials to ensure safety and compliance with regulations.
Taking the right precautions when using the C-Reactive Protein Assay Kit is crucial for obtaining accurate and reliable results. From proper storage to careful handling, each step plays a role in ensuring the kit's performance. By following these guidelines, you can maintain the integrity of your tests and ensure patient safety.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.