Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
CD4/CD8/CD3 Detection Kit (Flow Cytometry - FITC/PE/PerCP)
The CD4/CD8/CD3 Detection Kit is composed of phosphate buffer, gelatin protein stabilizer, sodium azide, and CD4/CD8/CD3 tricolor antibodies. These components work together to ensure accurate and reliable detection of T-cell subsets in human blood samples. The kit is designed for use with flow cytometry, providing precise quantitative analysis of lymphocyte populations.
Product English Name:
CD4/CD8/CD3 Detection Kit (Flow Cytometry - FITC/PE/PerCP)
Alias:
T-Cell Subset Detection Kit,Lymphocyte Phenotyping Kit
Intended Use:
This kit is used for the quantitative detection of T lymphocytes, helper/inducer T lymphocytes, and suppressor/cytotoxic T lymphocytes in human EDTA-anticoagulated whole blood. It is essential for immunophenotyping and monitoring immune system health, particularly in conditions such as HIV/AIDS, autoimmune diseases, and post-transplant immune monitoring.
Product Introduction

The CD4/CD8/CD3 Detection Kit is a specialized tool for immunologists and clinicians to analyze T-cell subsets in human blood. Utilizing flow cytometry, this kit provides precise and reproducible results, making it a critical component in diagnosing and monitoring immune-related conditions. Its tricolor antibody system ensures comprehensive detection of key lymphocyte populations.

1. The kit features a tricolor antibody system (FITC, PE, PerCP) for simultaneous detection of CD4, CD8, and CD3 markers. This allows for detailed analysis of T-cell subsets, providing insights into immune system functionality.
2. The composition includes phosphate buffer, gelatin protein stabilizer, sodium azide, and tricolor antibodies. These components are optimized for stability and accuracy, ensuring reliable performance in flow cytometry applications.
3. The primary use of this kit is to quantify T lymphocytes, helper/inducer T cells, and suppressor/cytotoxic T cells in human blood. It is widely used in clinical diagnostics, research, and immune monitoring.

The CD4/CD8/CD3 Detection Kit, also known as the T-Cell Subset Detection Kit, is a vital tool for immunophenotyping. Its tricolor antibody system and optimized components make it a reliable choice for clinicians and researchers alike. Whether you're monitoring immune health or diagnosing conditions, this kit delivers precise and actionable results.

Main Features

This detection kit offers high precision in quantifying T-cell subsets, making it indispensable for immune system analysis. Its tricolor antibody system ensures comprehensive detection, while its stable composition guarantees reliable results.

1. The tricolor antibody system (FITC, PE, PerCP) enables simultaneous detection of CD4, CD8, and CD3 markers, providing a detailed profile of T-cell subsets.
2. The kit includes a phosphate buffer and gelatin protein stabilizer, which maintain sample integrity and ensure accurate flow cytometry results.
3. Sodium azide is included as a preservative, enhancing the shelf life and stability of the reagents.
4. The kit is designed for use with EDTA-anticoagulated whole blood, making it compatible with standard clinical sample collection methods.
5. It provides absolute counts of T lymphocytes, helper/inducer T cells, and suppressor/cytotoxic T cells, essential for immune monitoring and diagnostics.

The CD4/CD8/CD3 Detection Kit stands out for its precision and reliability. Its tricolor antibody system and stable composition make it a go-to tool for immune system analysis. Whether you're a clinician or researcher, this kit simplifies complex immunophenotyping tasks.

Clinical Applications

This kit is widely used in clinical settings for immune monitoring, particularly in HIV/AIDS management, autoimmune disease diagnosis, and post-transplant immune surveillance. Its accuracy and reliability make it a trusted tool for clinicians.

1. In HIV/AIDS management, the kit is used to monitor CD4+ T-cell counts, a critical indicator of disease progression and treatment efficacy.
2. For autoimmune diseases, it helps assess immune system dysregulation by quantifying T-cell subsets.
3. Post-transplant patients benefit from its use in monitoring immune reconstitution and detecting graft-versus-host disease.
4. Researchers use the kit to study immune responses in various conditions, including infections and cancer.
5. It is also employed in vaccine development to evaluate immune system activation and response.

The CD4/CD8/CD3 Detection Kit is a versatile tool in clinical and research settings. Its applications range from HIV/AIDS monitoring to autoimmune disease diagnosis, making it an essential component of modern immunology.

Purchasing Guide

When purchasing this kit, consider factors such as product specifications, intended use, budget, and compatibility with your laboratory setup. This guide provides key insights to help you make an informed decision.

1. Product parameters: Ensure the kit includes the tricolor antibody system (FITC, PE, PerCP) and is compatible with your flow cytometry equipment.
2. Product types: Choose between research-grade and clinical-grade kits based on your intended use.
3. Budget considerations: Evaluate the cost per test and overall value, especially for high-throughput laboratories.
4. Usage scenarios: Assess whether the kit meets your needs for immune monitoring, research, or diagnostics.

Purchasing the right CD4/CD8/CD3 Detection Kit requires careful consideration of your specific needs. From product parameters to budget, this guide helps you navigate the decision-making process with confidence.

 Precautions

Proper handling and storage of the CD4/CD8/CD3 Detection Kit are essential to ensure accurate results. Follow these precautions to maintain kit integrity and performance.

1. Store the kit at the recommended temperature (2-8°C) to preserve antibody stability.
2. Avoid repeated freeze-thaw cycles, as this can degrade the antibodies and affect performance.
3. Use EDTA-anticoagulated whole blood samples for optimal results. Other anticoagulants may interfere with detection.
4. Follow the manufacturer's instructions for sample preparation and staining to ensure consistency.
5. Dispose of reagents and samples according to local biohazard waste regulations.

Handling the CD4/CD8/CD3 Detection Kit with care is crucial for reliable results. From storage to disposal, these precautions ensure the kit performs at its best, delivering accurate and actionable data.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files