The CD4 FITC/CD45RA PC5.5/CD62L PC7/MitoDye/CD8 AC7 Detection Kit is a sophisticated tool designed for flow cytometry analysis. It enables researchers and clinicians to accurately quantify and analyze T lymphocyte subsets in human blood samples. The kit includes a combination of multicolor antibodies and a fluorescent probe, ensuring precise and reliable results.
1. The kit features a unique combination of multicolor antibodies, including CD4 FITC, CD45RA PerCP-Cy5.5, CD62L PE-Cyanine7, and CD8 APC-Cyanine7, which are essential for identifying specific T cell subsets.
2. The composition includes a phosphate buffer with a pH of 7.4, containing NaH2PO4, NaCl, gelatin, and sodium azide, ensuring stability and optimal performance of the antibodies.
3. The primary use of this kit is for the quantitative detection of T lymphocyte subsets and their metabolic indicators in human whole blood, making it a valuable tool in immunology research and clinical diagnostics.
The CD4 FITC/CD45RA PC5.5/CD62L PC7/MitoDye/CD8 AC7 Detection Kit is a comprehensive solution for flow cytometry analysis. Its unique combination of antibodies and probes ensures accurate and reliable detection of T cell subsets, making it an indispensable tool in both research and clinical settings.
This detection kit offers a range of features designed to enhance the accuracy and efficiency of flow cytometry analysis. It includes multicolor antibodies, a fluorescent probe, and a lysing agent, all optimized for precise detection of T lymphocyte subsets.
1. The kit includes multicolor antibodies that specifically target CD4, CD45RA, CD62L, and CD8, allowing for detailed analysis of T cell subsets.
2. The fluorescent probe, MitoDye, is designed to provide clear and distinct signals, enhancing the accuracy of the detection process.
3. The lysing agent, a less than 10% ammonium chloride solution, ensures efficient red blood cell lysis without damaging the target cells.
4. The phosphate buffer maintains the stability of the antibodies and ensures optimal performance throughout the detection process.
5. The kit is designed for ease of use, with all components pre-formulated and ready for immediate use, reducing preparation time and potential errors.
The CD4 FITC/CD45RA PC5.5/CD62L PC7/MitoDye/CD8 AC7 Detection Kit is a powerful tool for flow cytometry analysis. Its combination of multicolor antibodies, a fluorescent probe, and a lysing agent ensures precise and reliable detection of T cell subsets, making it an essential tool for researchers and clinicians alike.
This detection kit is widely used in clinical applications for the analysis of T lymphocyte subsets in human blood samples. It is particularly valuable in immunology research, diagnostics, and monitoring of immune responses.
1. The kit is used in clinical diagnostics to assess the percentage of T lymphocyte subsets in patients with immune disorders.
2. It is employed in research settings to study the effects of various treatments on T cell populations.
3. The kit is also used in monitoring immune responses in patients undergoing immunotherapy or other immune-modulating therapies.
4. In clinical trials, the kit is used to evaluate the efficacy of new drugs targeting T cell subsets.
5. The kit is also used in basic immunology research to understand the role of T cells in various diseases and conditions.
The CD4 FITC/CD45RA PC5.5/CD62L PC7/MitoDye/CD8 AC7 Detection Kit is a versatile tool in clinical applications. Its ability to accurately quantify T lymphocyte subsets makes it invaluable in diagnostics, research, and monitoring of immune responses, providing critical insights into immune health and disease.
When purchasing this detection kit, it is important to consider the specific requirements of your research or clinical application. Factors such as product parameters, types, budget, and usage scenarios should be carefully evaluated.
1. Product parameters: Ensure that the kit includes all necessary components, such as multicolor antibodies, a fluorescent probe, and a lysing agent, and that they meet your specific research needs.
2. Product types: Consider the different types of kits available, such as those designed for specific T cell subsets or those with additional features like enhanced stability or ease of use.
3. Budget: Evaluate the cost of the kit in relation to your research budget, taking into account the number of samples you plan to analyze and the frequency of use.
4. Usage scenarios: Consider the specific applications for which you will use the kit, such as clinical diagnostics, research, or monitoring of immune responses, and choose a kit that is optimized for those applications.
Purchasing the CD4 FITC/CD45RA PC5.5/CD62L PC7/MitoDye/CD8 AC7 Detection Kit requires careful consideration of various factors, including product parameters, types, budget, and usage scenarios. By evaluating these factors, you can ensure that you select the right kit for your specific needs, whether for research or clinical applications.
When using this detection kit, it is important to follow all safety and handling precautions to ensure accurate results and prevent contamination or damage to the components.
1. Always wear appropriate personal protective equipment, including gloves and lab coats, when handling the kit components.
2. Ensure that all components are stored at the recommended temperatures and protected from light to maintain their stability and performance.
3. Follow the manufacturer's instructions for the preparation and use of the kit components, including the proper dilution of antibodies and the correct handling of the fluorescent probe.
4. Avoid cross-contamination by using clean and sterile equipment for each step of the detection process.
5. Dispose of all waste materials according to local regulations and guidelines for biohazardous waste.
Using the CD4 FITC/CD45RA PC5.5/CD62L PC7/MitoDye/CD8 AC7 Detection Kit requires careful attention to safety and handling precautions. By following these guidelines, you can ensure the accuracy of your results and maintain the integrity of the kit components, ultimately leading to successful and reliable flow cytometry analysis.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.