The CD3/CD16+CD56/CD45/CD19 Detection Kit is a specialized tool for flow cytometry analysis, designed to identify and quantify specific lymphocyte subsets in human blood. It is widely used in clinical diagnostics and research to assess immune system health and function. The kit includes high-quality antibodies and reagents, ensuring precise and reproducible results.
1. The kit features a combination of four-color antibodies targeting CD3, CD16+CD56, CD45, and CD19, enabling simultaneous detection of multiple lymphocyte subsets. This multiplexing capability enhances efficiency and reduces sample volume requirements.
2. The composition includes mouse anti-human antibodies and a lysing solution, optimized for flow cytometry. The antibodies are conjugated to fluorochromes, allowing for clear differentiation of cell populations during analysis.
3. Its primary use is in immunophenotyping, particularly for identifying T cells, B cells, and natural killer cells. This information is crucial for diagnosing immune disorders, monitoring treatment efficacy, and conducting immunological research.
The CD3/CD16+CD56/CD45/CD19 Detection Kit, also known as the Lymphocyte Subset Detection Kit, is a powerful tool for flow cytometry. Its ability to simultaneously detect multiple lymphocyte subsets makes it indispensable in both clinical and research settings. The kit's precision and reliability ensure accurate immune system profiling.
This kit enables simultaneous detection of T cells, B cells, and natural killer cells using four-color flow cytometry. It is designed for high accuracy, efficiency, and ease of use in clinical and research applications.
1. The kit utilizes four-color antibody combinations, allowing for the simultaneous detection of CD3, CD16+CD56, CD45, and CD19 markers. This multiplexing capability reduces the need for multiple assays.
2. It includes high-quality mouse anti-human antibodies, ensuring specificity and sensitivity in detecting lymphocyte subsets. The antibodies are conjugated to fluorochromes for clear signal detection.
3. The lysing solution is optimized for efficient red blood cell lysis, ensuring accurate white blood cell analysis without interference.
4. The kit is compatible with most flow cytometers, making it versatile for use in various laboratory settings.
5. It provides reproducible results, essential for longitudinal studies and clinical diagnostics.
The CD3/CD16+CD56/CD45/CD19 Detection Kit stands out for its multiplexing capability, high specificity, and compatibility with flow cytometers. Its ability to deliver consistent and accurate results makes it a trusted choice for immune system analysis.
This kit is widely used in clinical diagnostics to assess immune system health, monitor treatment responses, and diagnose immune disorders. It is also valuable in research for studying lymphocyte subsets and immune responses.
1. In clinical diagnostics, the kit is used to evaluate immune system function, particularly in patients with autoimmune diseases, infections, or undergoing immunotherapy.
2. It aids in monitoring treatment efficacy, such as in cancer patients receiving immunotherapy, by tracking changes in lymphocyte subsets.
3. The kit is essential for diagnosing primary and secondary immunodeficiencies, providing insights into immune cell populations.
4. Researchers use it to study immune responses in various conditions, including infectious diseases, cancer, and transplantation.
5. It is also employed in vaccine development and efficacy studies, helping to understand immune system activation.
The CD3/CD16+CD56/CD45/CD19 Detection Kit is a versatile tool in both clinical and research settings. Its ability to provide detailed immune system profiling makes it invaluable for diagnosing diseases, monitoring treatments, and advancing immunological research.
When purchasing this kit, consider factors such as product specifications, compatibility with your flow cytometer, budget, and intended applications. Ensure the kit meets your laboratory's requirements for accuracy and reproducibility.
1. Product parameters: Verify the antibody combinations, fluorochrome conjugates, and lysing solution specifications to ensure they align with your experimental needs.
2. Product types: Choose between pre-mixed or customizable kits based on your laboratory's workflow and sample volume.
3. Budget: Compare prices from different suppliers, considering the kit's quality, reliability, and included components.
4. Usage scenarios: Ensure the kit is suitable for your specific applications, such as clinical diagnostics or research studies.
Purchasing the CD3/CD16+CD56/CD45/CD19 Detection Kit requires careful consideration of product specifications, compatibility, and budget. Selecting the right kit ensures optimal performance and reliable results in your laboratory.
Proper handling and storage of the kit components are essential to maintain their performance. Follow the manufacturer's instructions for use, storage, and disposal to ensure accurate results and safety.
1. Store the kit at the recommended temperature to preserve antibody stability and reagent performance.
2. Avoid repeated freeze-thaw cycles, as they can degrade the antibodies and affect assay results.
3. Use appropriate personal protective equipment (PPE) when handling the kit components to prevent contamination and ensure safety.
4. Follow the recommended protocol for sample preparation and analysis to achieve consistent and reliable results.
5. Dispose of used reagents and samples according to local regulations and laboratory safety guidelines.
The CD3/CD16+CD56/CD45/CD19 Detection Kit requires careful handling and storage to ensure optimal performance. Adhering to the manufacturer's guidelines and laboratory safety protocols is crucial for obtaining accurate results and maintaining a safe working environment.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.