Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
CD3/CD16+CD56/CD45/CD19 Detection Kit (Flow Cytometry - FITC/PE/PerCP/APC)
This kit is composed of phosphate buffer, gelatin protein stabilizer, CD3/CD16+CD56/CD45/CD19 four-color antibodies, and hemolysin. It is designed for use with flow cytometry to analyze specific lymphocyte subsets in human blood samples. The components are optimized for accurate and reliable detection of immune cell populations.
Product English Name:
CD3/CD16+CD56/CD45/CD19 Detection Kit (Flow Cytometry - FITC/PE/PerCP/APC)
Alias:
Multicolor Flow Cytometry Kit,Lymphocyte Subset Detection Kit
Intended Use:
This kit is used for the quantitative detection of mature T lymphocytes (CD3+), B lymphocytes (CD19+), and natural killer cells (CD3-CD16+ and/or CD56+) in human whole blood samples after erythrocyte lysis. It is widely applied in immunology research, clinical diagnostics, and monitoring immune responses in various diseases.
Product Introduction

The CD3/CD16+CD56/CD45/CD19 Detection Kit is a state-of-the-art tool for flow cytometry, enabling precise identification and quantification of key lymphocyte subsets in human blood. It utilizes a combination of FITC, PE, PerCP, and APC fluorescent dyes to provide multi-parameter analysis, making it an essential tool for immunologists and clinicians.

1. This kit is designed with high specificity and sensitivity, ensuring accurate detection of lymphocyte subsets. The use of four-color antibodies allows for simultaneous analysis of multiple cell populations, reducing the need for multiple assays.
2. The kit includes a phosphate buffer for sample preparation, gelatin protein stabilizer to maintain antibody integrity, and hemolysin for efficient erythrocyte lysis. These components work together to ensure reliable and reproducible results.
3. It is primarily used in research and clinical settings to study immune system dynamics, diagnose immune disorders, and monitor treatment responses. Its versatility makes it suitable for both basic research and advanced clinical applications.

The CD3/CD16+CD56/CD45/CD19 Detection Kit, also known as the Multicolor Flow Cytometry Kit, is a powerful tool for analyzing immune cell populations. Its robust design and comprehensive components make it a go-to choice for researchers and clinicians alike.

Main Features

This kit offers high-precision detection of lymphocyte subsets using multi-color flow cytometry. It is designed for ease of use, reliability, and versatility in both research and clinical applications.

1. The kit provides simultaneous detection of T cells, B cells, and NK cells, enabling comprehensive immune profiling in a single assay.
2. It includes optimized reagents such as phosphate buffer, gelatin stabilizer, and hemolysin, ensuring consistent performance across different sample types.
3. The use of FITC, PE, PerCP, and APC fluorescent dyes allows for multi-parameter analysis, reducing the need for additional staining steps.
4. It is compatible with most flow cytometers, making it accessible to a wide range of laboratories and clinics.
5. The kit is designed for high reproducibility, ensuring reliable results for both research and diagnostic purposes.

The CD3/CD16+CD56/CD45/CD19 Detection Kit stands out for its precision, versatility, and ease of use. Whether you're studying immune responses or diagnosing diseases, this kit delivers consistent and reliable results.

Clinical Applications

This kit is widely used in clinical settings for immune monitoring, disease diagnosis, and treatment evaluation. It is particularly valuable in oncology, immunology, and infectious disease research.

1. In oncology, the kit is used to monitor immune cell populations in cancer patients, helping to assess the effectiveness of immunotherapy.
2. It is employed in immunology research to study the dynamics of T cells, B cells, and NK cells in various disease states.
3. The kit is used in infectious disease studies to evaluate immune responses to pathogens and vaccines.
4. It is also applied in autoimmune disease research to analyze changes in lymphocyte subsets and their role in disease progression.
5. Clinicians use this kit to diagnose immune deficiencies and monitor immune reconstitution after treatments such as bone marrow transplantation.

The CD3/CD16+CD56/CD45/CD19 Detection Kit is a versatile tool in clinical and research settings. Its ability to provide detailed immune profiling makes it indispensable for understanding and managing complex diseases.

Purchasing Guide

When purchasing this kit, consider factors such as product specifications, compatibility with your flow cytometer, and intended applications. Budget and usage scenarios should also guide your decision.

1. Product parameters: Ensure the kit includes all necessary components, such as antibodies, buffers, and stabilizers, and verify their concentrations and volumes.
2. Product types: Choose between standard and customized kits based on your specific research or clinical needs.
3. Budget considerations: Compare prices from different suppliers and consider bulk purchasing for cost savings.
4. Usage scenarios: Evaluate whether the kit is suitable for your laboratory setup, including the type of flow cytometer and sample processing capabilities.

Purchasing the CD3/CD16+CD56/CD45/CD19 Detection Kit requires careful consideration of your specific needs and laboratory setup. By focusing on product details and budget, you can ensure optimal performance and value.

 Precautions

Proper handling and storage of the kit components are essential to ensure accurate results. Follow all safety protocols and manufacturer guidelines.

1. Store the kit at the recommended temperature to maintain the stability of antibodies and reagents.
2. Avoid repeated freeze-thaw cycles, as this can degrade the performance of the components.
3. Use appropriate personal protective equipment (PPE) when handling samples and reagents to prevent contamination and exposure.
4. Follow the manufacturer's instructions for sample preparation and staining to ensure consistent results.
5. Regularly calibrate your flow cytometer to maintain accuracy and reproducibility in your analyses.

The CD3/CD16+CD56/CD45/CD19 Detection Kit requires careful handling and adherence to protocols. By following these precautions, you can ensure reliable and accurate results in your research or clinical work.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files