CD3-FITC/CD8-PE/CD45-PerCP/CD4-APC Fluorescent Monoclonal Antibody Kit (Flow Cytometry)
The CD3-FITC/CD8-PE/CD45-PerCP/CD4-APC Fluorescent Monoclonal Antibody Kit is composed of specific antibodies designed for flow cytometry. These antibodies target key markers on human lymphocytes, enabling precise identification and quantification of lymphocyte subsets in whole blood samples.
Product English Name:
CD3-FITC/CD8-PE/CD45-PerCP/CD4-APC Fluorescent Monoclonal Antibody Kit (Flow Cytometry)
Alias:
Flow Cytometry Antibody Kit,Lymphocyte Subset Detection Kit
Intended Use:
This kit is used to determine the percentage of mature lymphocyte subsets in lysed whole blood samples, including T lymphocytes (CD3+), helper/inducer T lymphocytes (CD3+CD4+), and suppressor/cytotoxic T lymphocytes (CD3+CD8+). It is essential for immunophenotyping and immune system analysis.
Product Introduction

The CD3-FITC/CD8-PE/CD45-PerCP/CD4-APC Fluorescent Monoclonal Antibody Kit is a specialized tool for flow cytometry, designed to identify and quantify specific lymphocyte subsets in human blood. It is widely used in immunology research and clinical diagnostics to assess immune system function and monitor disease progression.

1. The kit features high-specificity monoclonal antibodies conjugated to fluorescent dyes, ensuring accurate detection of lymphocyte subsets. The antibodies are optimized for flow cytometry, providing reliable and reproducible results.
2. The composition includes CD3-FITC, CD8-PE, CD45-PerCP, and CD4-APC antibodies, each targeting specific cell surface markers. These markers are critical for distinguishing between different lymphocyte populations.
3. The primary use of this kit is to analyze lymphocyte subsets in whole blood samples. It is particularly valuable in diagnosing immune disorders, monitoring HIV progression, and evaluating the efficacy of immunotherapies.

The CD3-FITC/CD8-PE/CD45-PerCP/CD4-APC Fluorescent Monoclonal Antibody Kit, also known as the Flow Cytometry Antibody Kit, is a powerful tool for immunophenotyping. Its precise antibody composition and reliable performance make it indispensable for both research and clinical applications.

Main Features

This kit offers high specificity and sensitivity for detecting lymphocyte subsets, making it ideal for flow cytometry-based immune system analysis.

1. The kit includes monoclonal antibodies conjugated to fluorescent dyes, ensuring precise targeting of CD3, CD4, CD8, and CD45 markers.
2. It provides a comprehensive solution for immunophenotyping, allowing researchers and clinicians to analyze multiple lymphocyte subsets simultaneously.
3. The antibodies are rigorously validated for flow cytometry, ensuring consistent and reproducible results across experiments.
4. The kit is compatible with whole blood samples, simplifying sample preparation and reducing processing time.
5. It is widely used in clinical diagnostics, particularly for monitoring immune system disorders and evaluating therapeutic interventions.

The CD3-FITC/CD8-PE/CD45-PerCP/CD4-APC Fluorescent Monoclonal Antibody Kit stands out for its precision and versatility. Its ability to detect multiple lymphocyte subsets simultaneously makes it a cornerstone in immunology research and diagnostics.

Clinical Applications

This kit is extensively used in clinical settings for immune system analysis, disease monitoring, and therapeutic evaluation.

1. It is employed in HIV/AIDS research to monitor CD4+ T cell counts, a critical indicator of disease progression.
2. The kit is used in autoimmune disease studies to assess lymphocyte subset imbalances and immune dysregulation.
3. It plays a key role in cancer immunotherapy research by evaluating the efficacy of treatments targeting specific lymphocyte populations.
4. Clinicians use this kit to diagnose primary immunodeficiency disorders by analyzing lymphocyte subset distributions.
5. It is also utilized in transplant medicine to monitor immune reconstitution and graft-versus-host disease.

The CD3-FITC/CD8-PE/CD45-PerCP/CD4-APC Fluorescent Monoclonal Antibody Kit is a versatile tool in clinical applications. Its ability to provide detailed insights into lymphocyte subsets makes it invaluable for disease diagnosis, monitoring, and treatment evaluation.

Purchasing Guide

When purchasing this kit, consider factors such as product specifications, intended use, budget, and compatibility with your flow cytometry system.

1. Evaluate the product parameters, including antibody specificity, fluorescence intensity, and stability, to ensure they meet your experimental requirements.
2. Choose the appropriate kit type based on your research or clinical needs, such as single-color or multi-color antibody panels.
3. Set a realistic budget, considering the kit's cost per test and the scale of your experiments.
4. Assess the compatibility of the kit with your flow cytometry instrument and software to avoid technical issues.

Purchasing the CD3-FITC/CD8-PE/CD45-PerCP/CD4-APC Fluorescent Monoclonal Antibody Kit requires careful consideration of technical specifications and practical needs. A well-informed decision ensures optimal performance and cost-effectiveness.

 Precautions

Proper handling and storage of the kit are essential to maintain antibody stability and ensure accurate results.

1. Store the kit at the recommended temperature to preserve antibody activity and fluorescence intensity.
2. Avoid repeated freeze-thaw cycles, as they can degrade antibody performance.
3. Follow the manufacturer's instructions for sample preparation and staining to achieve consistent results.
4. Use appropriate controls to validate your flow cytometry data and minimize experimental variability.
5. Dispose of reagents and samples according to local biosafety regulations to ensure laboratory safety.

The CD3-FITC/CD8-PE/CD45-PerCP/CD4-APC Fluorescent Monoclonal Antibody Kit requires careful handling and adherence to protocols. By following these precautions, you can maximize the kit's performance and reliability in your experiments.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files