Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
CD147 Detection Kit (Immunohistochemistry)
The CD147 Detection Kit is composed of normal goat serum solution, HAb18G/CD147 monoclonal antibody, goat anti-mouse antibody (polyclonal) - biotin, avidin-horseradish peroxidase, DAB chromogen, DAB chromogen diluent A, DAB chromogen diluent B, and PBS buffer (powder). These components are essential for the accurate detection of CD147 in tissue samples.
Product English Name:
CD147 Detection Kit (Immunohistochemistry)
Alias:
CD147 IHC Kit,HAb18G/CD147 Detection Kit
Intended Use:
This kit is specifically designed for the detection of CD147 in formalin-fixed, paraffin-embedded human tissue sections. It is particularly useful in identifying the distribution and expression of CD147 in epithelial-derived malignant tumors, including liver cancer, lung cancer, esophageal cancer, gastric cancer, colorectal cancer, breast cancer, ovarian cancer, and cervical cancer.
Product Introduction

The CD147 Detection Kit (Immunohistochemistry) is a specialized tool used in pathology and oncology research. It enables the precise identification of CD147, a protein that plays a significant role in cancer progression and metastasis. This kit is essential for researchers and clinicians studying epithelial-derived malignancies.

1. The CD147 Detection Kit is characterized by its high sensitivity and specificity, making it a reliable tool for detecting CD147 in various tissue samples. Its components are optimized to ensure accurate and reproducible results.
2. The kit includes a combination of antibodies and enzymes that work together to bind to CD147 in tissue sections. The use of DAB chromogen allows for clear visualization of CD147 expression under a microscope.
3. This kit is primarily used in research and clinical settings to study the role of CD147 in cancer. It helps in understanding the distribution and expression patterns of CD147 in different types of epithelial-derived malignancies.

The CD147 Detection Kit, also known as the HAb18G/CD147 Detection Kit, is a vital tool in cancer research. Its ability to accurately detect CD147 in tissue samples makes it indispensable for studying the role of this protein in cancer progression and metastasis.

Main Features

The CD147 Detection Kit offers high sensitivity and specificity for detecting CD147 in tissue samples. It is designed for use in immunohistochemistry, providing clear and reliable results.

1. The kit includes a monoclonal antibody specific to CD147, ensuring high specificity in detection.
2. The use of biotinylated secondary antibodies and avidin-horseradish peroxidase enhances the sensitivity of the detection process.
3. The DAB chromogen system provides a stable and visible signal, allowing for easy interpretation of results under a microscope.
4. The kit is optimized for use with formalin-fixed, paraffin-embedded tissue sections, making it suitable for a wide range of cancer research applications.
5. The inclusion of a PBS buffer ensures proper pH and ionic strength, which are critical for accurate antibody binding and detection.

The CD147 Detection Kit is a powerful tool for researchers and clinicians. Its high sensitivity, specificity, and ease of use make it an essential component in the study of CD147 in cancer.

Clinical Applications

The CD147 Detection Kit is widely used in clinical research to study the expression of CD147 in various cancers. It helps in understanding the role of CD147 in tumor progression and metastasis.

1. The kit is used to detect CD147 expression in liver cancer, providing insights into the protein's role in tumor growth and metastasis.
2. In lung cancer research, the kit helps in identifying CD147 expression patterns, which can be correlated with patient outcomes.
3. The kit is also used in esophageal cancer studies to understand the distribution of CD147 in tumor tissues.
4. In gastric cancer research, the kit aids in the detection of CD147, which is often overexpressed in these tumors.
5. The kit is valuable in breast cancer research, where CD147 expression is associated with aggressive tumor behavior.

The CD147 Detection Kit is a versatile tool in clinical research, providing valuable insights into the role of CD147 in various cancers. Its applications extend from basic research to clinical diagnostics, making it an indispensable resource for oncologists and pathologists.

Purchasing Guide

When purchasing the CD147 Detection Kit, it is important to consider the specific requirements of your research or clinical application. This guide provides key considerations for selecting the right kit.

1. Product Parameters: Ensure that the kit includes all necessary components, such as antibodies, enzymes, and buffers, and that they are optimized for your specific tissue type.
2. Product Type: Choose a kit that is compatible with your laboratory's equipment and protocols, such as those designed for immunohistochemistry.
3. Budget: Consider the cost of the kit in relation to your research budget, and ensure that it provides good value for the features and performance it offers.
4. Usage Scenarios: Evaluate the kit's suitability for your specific research or clinical application, such as its ability to detect CD147 in formalin-fixed, paraffin-embedded tissues.

Selecting the right CD147 Detection Kit requires careful consideration of your research needs and budget. By focusing on product parameters, type, and usage scenarios, you can ensure that you choose a kit that meets your requirements and delivers reliable results.

 Precautions

When using the CD147 Detection Kit, it is important to follow proper handling and storage procedures to ensure accurate and reliable results.

1. Always wear appropriate personal protective equipment (PPE) when handling the kit components, especially the DAB chromogen, which can be hazardous.
2. Store the kit components at the recommended temperatures to maintain their stability and effectiveness.
3. Follow the manufacturer's instructions carefully when preparing and using the kit components to avoid contamination and ensure accurate results.
4. Dispose of used reagents and materials according to local regulations and laboratory safety protocols.
5. Regularly calibrate and maintain laboratory equipment, such as microscopes and pipettes, to ensure accurate measurements and observations.

Proper handling and storage of the CD147 Detection Kit are essential for obtaining reliable results. By following safety protocols and manufacturer instructions, you can minimize risks and ensure the success of your research or clinical application.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files