Medical Instruments Encyclopedia
Home > Medical Instruments Encyclopedia
C-Peptide Calibrator
The C-Peptide Calibrator consists of six different concentration levels, labeled S0 to S5. S0 has a zero concentration, while S1 to S5 have concentrations of approximately 0.05, 0.24, 1.20, 6.00, and 30.0 ng/mL, respectively. The kit includes a calibration card. Each calibrator contains HEPES buffer (pH 7.70-7.80), 7.0% m/v bovine serum albumin (BSA), 0.02% v/v surfactant, 0.5% v/v preservative, and less than 0.1% sodium azide. S1 to S5 also include varying concentrations of C-Peptide antigen.
Product English Name:
C-Peptide Calibrator
Alias:
C-Peptide Standard,C-Peptide Reference
Intended Use:
The C-Peptide Calibrator is used to calibrate the Access C-Peptide Assay, enabling the quantitative measurement of C-Peptide levels in human serum and plasma using the Access Immunoassay System. This is crucial for diagnosing and monitoring conditions related to insulin production, such as diabetes.
Product Introduction

The C-Peptide Calibrator is a critical component in the accurate measurement of C-Peptide levels in human serum and plasma. It is designed to ensure the precision and reliability of the Access C-Peptide Assay, which is widely used in clinical diagnostics. The calibrator set includes six different concentration levels, each carefully formulated to provide a reliable reference for the assay.

1. The C-Peptide Calibrator is characterized by its high precision and stability, ensuring consistent performance across different batches. It is formulated with HEPES buffer, BSA, and other stabilizing agents to maintain its integrity over time.
2. The composition of the calibrator includes six different concentration levels, each containing HEPES buffer, BSA, surfactant, preservative, and sodium azide. S1 to S5 also include varying concentrations of C-Peptide antigen, making it suitable for a wide range of calibration needs.
3. The primary use of the C-Peptide Calibrator is to calibrate the Access C-Peptide Assay, which is used to measure C-Peptide levels in human serum and plasma. This is essential for diagnosing and monitoring conditions such as diabetes, where accurate measurement of insulin production is critical.

The C-Peptide Calibrator, also known as the C-Peptide Standard or Reference, is a vital tool in clinical diagnostics. Its precise formulation and multiple concentration levels make it an indispensable component for ensuring the accuracy of C-Peptide measurements, which are crucial for managing conditions like diabetes.

Main Features

The C-Peptide Calibrator is designed to provide accurate and reliable calibration for the Access C-Peptide Assay. Its key features include high precision, stability, and a wide range of concentration levels to suit various calibration needs.

1. High Precision: The C-Peptide Calibrator is formulated to ensure high precision in calibration, reducing variability and ensuring consistent results across different assays.
2. Stability: The inclusion of HEPES buffer, BSA, and other stabilizing agents ensures that the calibrator remains stable over time, even under varying storage conditions.
3. Multiple Concentration Levels: With six different concentration levels, the calibrator can be used to calibrate a wide range of assays, from low to high C-Peptide concentrations.
4. Compatibility: The calibrator is specifically designed for use with the Access Immunoassay System, ensuring seamless integration and accurate results.
5. Quality Control: Each batch of the C-Peptide Calibrator undergoes rigorous quality control testing to ensure that it meets the highest standards of accuracy and reliability.

The C-Peptide Calibrator stands out for its precision, stability, and versatility. Its multiple concentration levels and compatibility with the Access Immunoassay System make it an essential tool for accurate C-Peptide measurement, which is critical in the diagnosis and management of diabetes.

Clinical Applications

The C-Peptide Calibrator is primarily used in clinical settings to calibrate the Access C-Peptide Assay, which is essential for measuring C-Peptide levels in patients. This is particularly important in the diagnosis and management of diabetes.

1. Diabetes Diagnosis: The C-Peptide Calibrator is used to calibrate assays that measure C-Peptide levels, which are crucial for diagnosing diabetes and distinguishing between type 1 and type 2 diabetes.
2. Monitoring Insulin Production: Accurate measurement of C-Peptide levels helps in monitoring insulin production in patients, which is essential for managing diabetes and adjusting treatment plans.
3. Research Applications: The calibrator is also used in research settings to study the role of C-Peptide in various metabolic processes and its potential implications in other diseases.
4. Clinical Trials: In clinical trials, the C-Peptide Calibrator ensures that C-Peptide measurements are accurate and consistent, which is critical for evaluating the efficacy of new treatments.
5. Routine Testing: The calibrator is used in routine clinical testing to ensure that C-Peptide levels are accurately measured, providing reliable data for patient care.

The C-Peptide Calibrator plays a crucial role in clinical diagnostics, particularly in the diagnosis and management of diabetes. Its use in research and clinical trials further underscores its importance in advancing our understanding of metabolic diseases and improving patient outcomes.

Purchasing Guide

When purchasing the C-Peptide Calibrator, it is important to consider factors such as product specifications, types, budget, and intended use to ensure that you select the right product for your needs.

1. Product Specifications: Ensure that the calibrator meets the required specifications for your assay, including concentration levels and compatibility with your equipment.
2. Product Types: There are different types of C-Peptide Calibrators available, so choose one that best fits your specific application, whether for clinical diagnostics or research.
3. Budget: Consider your budget when selecting a calibrator, but also weigh the cost against the importance of accuracy and reliability in your measurements.
4. Intended Use: Think about how the calibrator will be used—whether for routine testing, research, or clinical trials—and select a product that aligns with your intended use.

Selecting the right C-Peptide Calibrator involves careful consideration of product specifications, types, budget, and intended use. By taking these factors into account, you can ensure that you choose a calibrator that meets your needs and provides accurate, reliable results.

 Precautions

When using the C-Peptide Calibrator, it is important to follow proper handling and storage procedures to ensure accurate results and maintain the integrity of the product.

1. Storage: Store the calibrator at the recommended temperature to maintain its stability and prevent degradation.
2. Handling: Handle the calibrator with care to avoid contamination, which could affect the accuracy of your results.
3. Expiration Date: Always check the expiration date before use, and do not use the calibrator if it has expired.
4. Calibration Procedure: Follow the recommended calibration procedure to ensure that your assay is properly calibrated and that your results are accurate.
5. Disposal: Dispose of used calibrators according to local regulations and guidelines to ensure safety and environmental compliance.

Proper handling, storage, and disposal of the C-Peptide Calibrator are essential to ensure accurate results and maintain the integrity of the product. By following these precautions, you can ensure that your assays are properly calibrated and that your results are reliable.

Easy procurement

We have the latest medical device product database in China, which can quickly meet your procurement needs.

Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.

Quickly respond to your procurement needs:
Upload your purchase list
Support EXCEL/PDF/Word/compressed files