The Creatine Kinase Isoenzyme Assay Kit (Immunoinhibition Method) is a specialized diagnostic tool used to measure the activity of creatine kinase isoenzymes in human serum. This kit is essential for diagnosing and monitoring cardiac conditions, particularly myocardial infarction. It employs an immunoinhibition method to ensure high specificity and accuracy in detecting CK-MB, the isoenzyme most associated with heart muscle damage.
1. The kit is characterized by its high sensitivity and specificity, making it a reliable tool for detecting CK-MB in serum. It uses an immunoinhibition method to selectively inhibit non-target isoenzymes, ensuring accurate results.
2. The kit is composed of two reagents: R1 and R2. R1 contains a mixture of stabilizing agents, buffers, and antibodies, while R2 includes substrates and enzymes necessary for the enzymatic reaction. Together, these components create a robust system for measuring CK-MB activity.
3. The primary use of this kit is in clinical diagnostics, particularly for assessing cardiac health. It is commonly used in hospitals and laboratories to diagnose myocardial infarction, monitor treatment efficacy, and evaluate heart muscle damage.
The Creatine Kinase Isoenzyme Assay Kit, also known as the CK-MB Assay Kit, is a vital tool in cardiac diagnostics. Its high specificity and sensitivity make it indispensable for detecting heart muscle damage. With its carefully formulated reagents, this kit ensures accurate and reliable results, making it a trusted choice for clinicians and laboratory professionals.
This kit offers high specificity and sensitivity in detecting CK-MB isoenzyme activity. It is designed for ease of use, providing reliable results in clinical settings.
1. The kit employs an immunoinhibition method, which selectively inhibits non-target isoenzymes, ensuring accurate detection of CK-MB.
2. It includes two reagents, R1 and R2, which are optimized for stability and performance, ensuring consistent results over time.
3. The kit is designed for high-throughput laboratories, allowing for efficient processing of multiple samples simultaneously.
4. It provides a wide dynamic range, enabling the detection of both low and high levels of CK-MB activity in serum.
5. The kit is compatible with most automated analyzers, making it a versatile choice for clinical laboratories.
The Creatine Kinase Isoenzyme Assay Kit stands out for its precision and reliability. Its immunoinhibition method ensures accurate results, while its compatibility with automated systems makes it a practical choice for busy laboratories. Whether diagnosing heart conditions or monitoring treatment, this kit delivers consistent performance.
This kit is primarily used in clinical settings to diagnose and monitor cardiac conditions, particularly myocardial infarction. It is also used in research to study heart muscle damage.
1. In clinical diagnostics, the kit is used to measure CK-MB levels in patients suspected of having a myocardial infarction, providing critical information for diagnosis and treatment.
2. It is also used to monitor patients undergoing treatment for heart conditions, helping clinicians assess the effectiveness of therapies.
3. The kit is valuable in emergency settings, where rapid and accurate diagnosis of heart attacks is crucial.
4. In research, the kit is used to study the mechanisms of heart muscle damage and the effects of various treatments on CK-MB levels.
5. It is also used in epidemiological studies to assess the prevalence of cardiac conditions in different populations.
The Creatine Kinase Isoenzyme Assay Kit is a cornerstone in cardiac diagnostics. Its ability to accurately measure CK-MB levels makes it indispensable in diagnosing and monitoring heart conditions. From emergency rooms to research labs, this kit plays a vital role in advancing cardiac care.
When purchasing this kit, consider factors such as product specifications, intended use, budget, and compatibility with existing laboratory equipment.
1. Product parameters: Ensure the kit meets your laboratory's requirements for sensitivity, specificity, and dynamic range.
2. Product type: Choose between manual and automated kits based on your laboratory's workflow and equipment.
3. Budget: Consider the cost per test and the overall value of the kit, including its shelf life and storage requirements.
4. Usage scenarios: Evaluate the kit's suitability for your specific applications, such as high-throughput testing or emergency diagnostics.
Selecting the right Creatine Kinase Isoenzyme Assay Kit requires careful consideration of your laboratory's needs. From product specifications to budget constraints, each factor plays a role in ensuring you choose a kit that delivers reliable and accurate results.
Proper handling and storage of the kit are essential to ensure accurate results. Follow all instructions carefully to avoid contamination or degradation of reagents.
1. Store the kit at the recommended temperature to maintain reagent stability and performance.
2. Avoid cross-contamination by using clean pipettes and tips for each sample.
3. Follow the recommended protocol for sample preparation and analysis to ensure accurate results.
4. Dispose of used reagents and samples according to local regulations to ensure safety and environmental compliance.
5. Regularly calibrate and maintain laboratory equipment to ensure consistent performance of the kit.
Using the Creatine Kinase Isoenzyme Assay Kit requires attention to detail. From proper storage to careful handling, each step is crucial to obtaining reliable results. By following the guidelines, you can ensure the kit performs as intended, providing accurate and actionable data for patient care.
We have the latest medical device product database in China, which can quickly meet your procurement needs.