The CD3-FITC/CD16+56-PE/CD45-PerCP-Cy5.5/CD4-PC7/CD19-APC/CD8-APC-Cy7 Fluorescent Monoclonal Antibody Kit is a specialized tool for flow cytometry analysis. It enables precise identification and quantification of various lymphocyte subsets in human blood, providing critical insights into immune system function and disease states.
1. The kit features a combination of six fluorescent monoclonal antibodies, each targeting specific cell surface markers. This allows for simultaneous detection of multiple lymphocyte subsets in a single sample, enhancing efficiency and accuracy.
2. The antibodies are formulated in a phosphate-buffered saline solution with stabilizing agents (0.2% BSA and 1‰ ProClin 300) to ensure stability and reliability during storage and use.
3. Designed for use with flow cytometry, this kit is essential for research and clinical diagnostics, particularly in immunology, oncology, and infectious disease studies.
This antibody kit is a powerful tool for researchers and clinicians alike. Its ability to simultaneously detect multiple lymphocyte subsets makes it invaluable for understanding immune responses and diagnosing diseases. The carefully formulated antibodies ensure consistent performance, making it a reliable choice for flow cytometry applications.
The kit's main features include its ability to detect multiple lymphocyte subsets simultaneously, its stability in storage, and its compatibility with flow cytometry systems.
1. The kit includes six fluorescent monoclonal antibodies, each targeting specific markers (CD3, CD16+56, CD45, CD4, CD19, and CD8), enabling comprehensive analysis of lymphocyte subsets.
2. The antibodies are dissolved in a phosphate-buffered saline solution with stabilizing agents, ensuring long-term stability and consistent performance.
3. Designed for use with flow cytometry, the kit provides high sensitivity and specificity, making it suitable for both research and clinical diagnostics.
4. The kit is optimized for use with lysed whole blood samples, simplifying sample preparation and reducing processing time.
5. It supports quantitative analysis, allowing researchers to determine the percentage of each lymphocyte subset in a sample, which is crucial for understanding immune system dynamics.
This antibody kit stands out for its versatility and reliability. Whether you're studying immune responses or diagnosing diseases, its ability to detect multiple lymphocyte subsets with high accuracy makes it an indispensable tool in the lab.
The kit is widely used in clinical and research settings for immune system analysis, disease diagnosis, and monitoring treatment responses.
1. In clinical diagnostics, the kit is used to identify and quantify lymphocyte subsets in patients with immune disorders, infections, or cancers.
2. Researchers use the kit to study immune responses in various diseases, including autoimmune disorders, viral infections, and cancer immunotherapy.
3. The kit is also employed in monitoring the effects of treatments, such as chemotherapy or immunotherapy, by tracking changes in lymphocyte subsets over time.
4. In transplantation medicine, the kit helps assess immune reconstitution and detect graft-versus-host disease.
5. It is also used in vaccine development to evaluate immune responses and determine vaccine efficacy.
This antibody kit has a broad range of applications, from diagnosing diseases to advancing research. Its ability to provide detailed insights into immune system function makes it a valuable asset in both clinical and research settings.
When purchasing this kit, consider factors such as product specifications, intended use, budget, and compatibility with your flow cytometry system.
1. Product specifications: Ensure the kit includes all necessary antibodies and is compatible with your flow cytometry system.
2. Product type: Choose the appropriate kit based on your research or clinical needs, such as lymphocyte subset analysis or immune monitoring.
3. Budget: Compare prices from different suppliers and consider bulk purchasing for cost savings.
4. Usage scenarios: Evaluate the kit's suitability for your specific applications, such as clinical diagnostics, research, or vaccine development.
Purchasing this kit requires careful consideration of your specific needs and budget. By selecting the right product and supplier, you can ensure optimal performance and value for your investment.
Proper handling and storage of the kit are essential to ensure accurate results and maintain antibody stability.
1. Store the kit at the recommended temperature (usually 2-8°C) to preserve antibody stability and performance.
2. Avoid repeated freeze-thaw cycles, as this can degrade the antibodies and affect their binding efficiency.
3. Follow the manufacturer's instructions for sample preparation and staining to ensure consistent and reliable results.
4. Use appropriate controls, such as unstained samples and single-color controls, to validate your flow cytometry results.
5. Dispose of used reagents and samples according to local regulations and safety guidelines.
Taking proper care of this kit is crucial for achieving accurate and reliable results. By following the recommended storage and handling procedures, you can maximize the kit's performance and extend its shelf life.
We have the latest medical device product database in China, which can quickly meet your procurement needs.
Submit your purchase list, and we will reply to your inquiry within half an hour at the earliest.